4.
Mounting
The signal conditioners are mounted on standard TS 35 rails.
5.
Electrical connection
Terminal assignments
1 Current input max. 20 mA
2 Voltage input max. 10 V
3 Input GND
4 Supply voltage + 24 Vdc (cross-connected)
5 Supply voltage 0V (cross-connected)
6 Supply voltage 0V (cross-connected)
7 Relay A contakt 11
8 Relay A contakt 12
9 Relay A contakt 14
10 Relay B contakt 21
11 Relay B contakt 22
12 Relay B contakt 24
Wire cross-section max. 2.5 mm
Multi-wire conncection max. 1 mm
(two wires with same cross-section)

5.1 Technical Data

Supply voltage
Operating temperature
Voltage supply via plug-in jumper. Operating carrying capacity of
cross-connection ^ 2 A
6
2
2
18 ... 30 Vdc/approx. 1 W
0 °C ... +55 °C
10
11 12
7 8
9
1 2 3
4 5 6