10.
Technical Specifications
NE 100 S Diversity Receiver
Operating principle . . . . . . . . . . . . . . . True diversity receiver (VHF)
Frequency range . . . . . . . . . . . . . . . . . 1 frequency between 174 - 240 MHz
Switching bandwidth . . . . . . . . . . . . . 24 MHz
Antenna connection . . . . . . . . . . . . . . 2 x TNC
Signal-to-noise ratio . . . . . . . . . . . . . . ≥ 100 dB(A)
T.H.D. . . . . . . . . . . . . . . . . . . . . . . . . . . < 0.5% at 1 kHz
Squelch . . . . . . . . . . . . . . . . . . . . . . . . . adjustable
Power supply . . . . . . . . . . . . . . . . . . . . 12 V - 15 V DC
Mains . . . . . . . . . . . . . . . . . . . . . . . . . . 110 V - 240 V AC (power supply unit)
Dimensions (L x W x H) . . . . . . . . . . . . 210 x 175 x 44 mm
Weight . . . . . . . . . . . . . . . . . . . . . . . . . 700 g
SDM 168 / SEM 180 Handheld Transmitter
Polar pattern . . . . . . . . . . . . . . . . . . . . Supercardioid (SDM 168)
Transducer type . . . . . . . . . . . . . . . . . . Dynamic (SDM 168)
Frequency range . . . . . . . . . . . . . . . . . 1 frequency between 174 - 240 MHz
Modulation . . . . . . . . . . . . . . . . . . . . . FM
Radiated transmitter power . . . . . . . . max. 10 mW
AF transmission range . . . . . . . . . . . . . 50 - 15,000 Hz
Transmission range . . . . . . . . . . . . . . . 100 m
Signal-to-noise ratio . . . . . . . . . . . . . . ≥ 100 dB
T.H.D. . . . . . . . . . . . . . . . . . . . . . . . . . . < 0.5% at 1 kHz
Power supply . . . . . . . . . . . . . . . . . . . . 1 x 9 V battery or rechargeable batteries
Operating time . . . . . . . . . . . . . . . . . . up to 15 hours with alkaline battery
Dimensions . . . . . . . . . . . . . . . . . . . . . . Length: 230 mm, Shaftø: 33/37 mm
Weight . . . . . . . . . . . . . . . . . . . . . . . . . 220 g (SDM 168), 230 g (SEM 180)
TS 100 Mk II Beltpack Transmitter
Frequency range . . . . . . . . . . . . . . . . . 1 frequency between 174 - 240 MHz
Modulation . . . . . . . . . . . . . . . . . . . . . FM
Radiated transmitter power . . . . . . . . max. 10 mW
Frequency response . . . . . . . . . . . . . . . 50 Hz - 18,000 Hz
Transmission range . . . . . . . . . . . . . . . 100 m
Gain . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 mV - 0.3 V adjustable, at nominal deviation
Signal-to-noise ratio . . . . . . . . . . . . . . ≥ 100 dB
T.H.D. . . . . . . . . . . . . . . . . . . . . . . . . . . < 0.5% at 1 kHz
Power supply . . . . . . . . . . . . . . . . . . . . 1 x 9 V battery or rechargeable battery
Operating time . . . . . . . . . . . . . . . . . . up to 15 hours with alkaline battery
Dimensions (L x W x D) . . . . . . . . . . . . 105 x 63 x 21 mm
Weight . . . . . . . . . . . . . . . . . . . . . . . . . 85 g
Cardioid (SEM 180)
Electret condenser (SEM 180)
39