Operating the generator
A
NOTICE!
Do not run the generator over 70 % of the maximum constant out-
put for the first 50 operating hours (run-in phase).
I
NOTE
Run the generator at a maximum of approx. 75 % of the maximum
continuous load after the run-in phase.
By doing this you can prolong the service life of the generator and
maximise its efficiency.
8.1
Basic notes on operation
!
CAUTION! Beware of injury
Do not insert your fingers or objects into the air nozzles or the
intake grille.
Please note the following basic information:
When operating the generator at low temperatures (< 0 °C) you have to
use winter diesel fuel or you have to add a percentage of petrol to the
diesel oil according to the following table:
Ambient Temperature
–10 to 0 °C
–15 to –10 °C
–20 to –15 °C
Always check the oil level before use (chapter "Checking the oil level" on
page 19).
Even small overloads in the long-run will cause the generator to stop.
Leave the generator running for a few minutes after use without any con-
sumers before stopping it.
Abrupt braking, accelerating and driving round bends in the vehicle can
cause problems in the generator's pump system and lead to unwanted
shutdown.
If you are not using your generator for a longer period of time, start it up
at least every 10 days and leave it running for 15 minutes or more.
EN
Summer diesel
20 %
30 %
30 %
Operating the generator
Winter diesel
–
–
20 %