TEC40D
9.5
Mounting the control panel
Please observe the following instructions for the installation location:
Observe the length of the extension cable from the control panel to the
generator.
➤ Drill the holes as shown in fig. 0, page 6.
➤ Insert the plug into the control panel.
➤ Screw on the control panel.
10
Connecting the electrical power to the
generator
D
DANGER! Danger of electrocution
Make sure there is no voltage at electrically operated components
before carrying out work on them!
I
NOTE
Observe the applicable guidelines in the country of the consumer.
10.1
Important notes on the electrical connection
Only a qualified electrician should connect the generator to the electrical
power.
Check that the voltage specification on the type plate is the same as that
of the power supply.
Do not lay the 230 Vw mains cable and the 12 Vg cable together in the
same cable duct.
Do not lay cables which are loose or bent next to electrically conductive
material (metal).
Connect the generator to a power circuit which can supply the necessary
current (see chapter "Technical data" on page 24).
Select the cross-section of the cable as follows:
– 230 V: 4 mm²
– Battery charger: 2.5 mm²
– Starter battery connection (length < 6 m): 16 mm²
– Starter battery connection (length > 6 m): 25 mm²
EN
Connecting the electrical power to the generator
19