Operating the generator

Displays
No. in
fig. 3,
Description
page 4
6
AC supply
7
Constant output
8
Operating hours
9
DC voltage
10
Messages
8
Operating the generator
A
NOTICE! Damage hazard
Do not run the generator over 70 % of the maximum constant output for
the first 50 operating hours (run-in phase).
I
NOTE
By doing this you can prolong the service life of the generator and
optimise its output:
run the generator at a maximum of approx. 75 % of the maximum
continuous load after the run-in phase.
8.1

Basic notes on operation

!
CAUTION! Beware of injury
Do not insert your fingers or objects into the air nozzles or the intake
grille.
Please note the following basic information:
• Always check the oil level before use (chapter "Checking the oil level" on
page 18).
• Even small overloads in the long-run will cause the generator to stop.
• Leave the generator running for a few minutes after use without any consumers
before stopping it.
14
Actual voltage output
Current capacity of connected consumer
Time the generator is in operation
Battery charging voltage
Status reports of the generator (see chapter
"Display messages" on page 16)
TEC60EV
EN