Checking the oil level

!
CAUTION!
Hot oil can cause burns.
Only check the oil level when the generator is switched off.
I
NOTE
The generator must be level.
Always check the oil level before use. To do this, proceed as follows:
➤ Open the generator cover.
➤ Switch the generator to no function with the main switch (fig. 4 1,
page 4).
➤ Disconnect the positive terminal of the supply battery.
➤ Take the dipstick (fig. 4 2, page 4) out of the filler neck (fig. 4 3,
page 4).
➤ Clean the dipstick (fig. 4 2, page 4) with a cloth.
➤ Put the dipstick (fig. 4 2, page 4) back into the filler neck (fig. 4 3,
page 4).
➤ Take the dipstick (fig. 4 2, page 4) out of the filler neck.
➤ Check that the oil level is between the notch (maximum filling level) and
the tip of the dipstick.
If not, top up with more oil.
➤ Put the dipstick (fig. 4 2, page 4) back into the filler neck (fig. 4 3,
page 4).
➤ Connect the generator to the positive terminal of the supply battery.
➤ Switch the generator to standby with the main switch (fig. 4 1, page 4).
➤ Close the generator cover.