Operating the generator
Display message
Description
OVER TEMPERATURE
The inverter temperature is
too high.
LOW POWER ENGINE
The inverter supply voltage
has dropped.
GEN CAL
A message appears when the
generator is started up; it
shows the calibration phase
which takes place before
each start-up. The generator
does not supply any voltage.
GEN WAIT
A message appears while
you are waiting for the
generator to start again.
GEN ON
The generator is operating
normally.
GEN OFF
18
Generator behaviour
The inverter switches off,
therefore no voltage is sup-
plied to cool the generator,
but the engine carries on
running.
The generator stops.
The generator is running but
does not supply any voltage.
The generator is switched off. Wait until the message has
Normal mode
The generator is in stand-by
and can be started.
TEC40D
Measures
Leave the generator to cool
down for a few minutes then
start up the generator again.
Reduce the connected load
and start the generator again.
Wait a moment.
disappeared then attempt
ignition again.