9. Cleaning
NOTICE
Cleaning with compressed air
If compressed air is used for cleaning there is a risk that metal chips may be blown into the thread
and slots.
» Do not use compressed air to clean clamping devices.
Do not use chemical, alcoholic, abrasive or solvent-based cleaning agents. Use a cleaning cloth to
clean the centring vice.
10. Storage
When putting away the centring vice, take care not to damage the base body or projecting com-
ponents. Place the centring vice on an underlay of wood, rubber or plastic. Before prolonged stor-
age, thoroughly clean the centring vice and apply preservative to it (see Grease the spindle [} 26]
and Grease the guides [} 26]) and protect it with a cover against dust and coarse dirt.
11. Disposal
Comply with the national and regional environmental protection and disposal regulations for cor-
rect disposal or recycling. Segregate items into metals, non-metals, composite materials and con-
sumables and dispose of them responsibly.
12. Spare parts
Use only original spare parts and wearing parts.
13. Technical data
13.1. CENTRING VICE
Size
Width in mm
Length in mm
Height in mm
Pivot angle in °
Weight in kg
Clamping force max. in kN
Torque max. in Nm
80S
80SP
80
80
170
170
40
40
-
± 2
3.240
3.228
25
25
85
85
www.hoffmann-group.com
80M
80MP
80
80
220
220
40
40
-
± 2
3.942
3.930
25
25
85
85
en
27