Temperature Display; Flame Height; Fan Speed - Napoleon Fireplaces HD81NT Instructions D'installation Et D'opération

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

8.4

TEMPERATURE DISPLAY

A.
With the system in the "OFF" position, press the
Temperature Key and the Mode Key at the same
time to change from degrees F to C.
B.
Look at the LCD screen on the Transmitter to
verify that a C or F is visible to the right of the
Room Temperature display.
8.5

FLAME HEIGHT

The remote control has six (6) fl ame levels. With the
system on and the fl ame level at the maximum, press
the Down Arrow Key once and it will reduce the fl ame
height by one step until the fl ame is turned off.
The Up Arrow Key will increase the fl ame height each
time it is pressed. If the Up Arrow Key is pressed while
the system is on but the fl ame is off, the fl ame will
come on the high position. A single "beep" will confi rm
reception of the command.
8.6

FAN SPEED

If the appliance is equipped with a hot air circulating fan,
the speed of the fan can be controlled by the remote
system. The fan speed can be adjusted through six (6)
speeds.
A.
Use the Mode key to guide you to the fan control
icon.
B.
Use the Up/Down Arrow keys to turn ON/OFF or
adjust the fan speed. A single "beep" will confi rm
reception of the command.
NOTE: When the desired blower speed is selected, the blower will automatically come on 5 minutes
after the main burner has been turned on and remain on twelve minutes after it has been turned off.
°F
73
35.5A
76
°F
OFF
FLAME OFF
76
°F
FLAME AT LEVEL 5
FLAME AT "HI" LEVEL 6
35.8A
76
°F
68
35.9B
37
°C
EN
23
76
°F
FLAME AT LEVEL 1
76
°F
Hi
76
°F
Hi
W415-1406 / 11.19.14

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Hd81pt

Table des Matières