Programming

Manager Mode

Manager mode allows access to view and
change the programming, including:
y Adjust timers
y Adjust setpoint temperature
y Adjust temperature units (°F/°C)
y Adjust beeper (three volume levels)
y View elapsed usage time
y View errors
y View internal control
Board temperature
y View power line information
To enter Manager Mode:
1.
Press and hold the Program button
until the unit beeps (about 5 seconds).
Release the button.
2.
The unit enters Manager Mode at
the Adjust Timers option. Press the
desired timer and use the Up and
Down arrow buttons to change the
time as desired. Press the Program
button to save the change and display
the Adjust Setpoint Temperature
option.
3.
Use the Up and Down arrow buttons
to change the setpoint temperature
as desired. The default is 300 °F (149
°C). Press the Program button to save
the change and display the Adjust
Temperature Units option.
4.
Use the Up and Down arrow buttons
to select Fahrenheit and Celsius
temperature units. Press the Program
button to save the change and display
the Adjust Beeper option.
5.
Use the Up and Down arrow buttons
to change the beeper setting. Three
options are available with variable
volumes and sound. Press the
Program button to save the change
and display the View Elapsed Time
option.
6.
The View Elapsed Usage Time option
shows the total time the unit has been
in operation. This option cannot be
edited. Press the Program button to
move to the next option, View Errors.
7.
The View Errors option shows any
errors that have occurred. This
option cannot be edited. Press the
Program button to move to the next
option, View Internal Control Board
Temperature.
P/N 1011587 Rev. C 11/20
Power button
Start
button
8.
The View Internal Control Board
Temperature shows the current
ambient temperature of the control
board. This option cannot be edited.
Press the Program button to move
to the next option, View Power Line
Information.
9.
The View Power Line Information
option shows power usage
information. This option cannot be
edited. Press the Program button to
return to the Adjust Timers option.
From here, another timer can be
selected for adjustment. Waiting for
10 seconds will return the unit to
Operation Mode.
7
Down arrow
Up arrow
Program
Extra 1
button
button
Figure 5. Control Panel
Timer
buttons
(4)
Stop
button
®