solve the problem nonetheless, approach a qualified
specialist.
Prior to maintenance and cleaning, turn the device
off and unplug it.
Danger of electric shock.
Symptom
Possible cause
The engine
The device is not
doesn't start
plugged into the
grid
The socket is
defective
The fuse has blown
The extension cord
is damaged
The engine
The fuse has blown
stops
The network
voltage is not right
The fuse has
Too weak a fuse
blown
Excessive
The nozzle is partly
effective
clogged
pressure
Pulsing
There's air in the
pressure
water hose or in
the pump
The water supply is
incorrect
Clogged water filter
The water hose is
clamped or broken
The pressure is
Worn-out nozzle
stable yet too
Worn-out
low
Start/Stop valve
The engine is
The water supply is
running, yet
not connected
there is no
The filter is clogged
effective
pressure
The high-
The pump or the
pressure
spray gun leaks
cleaner turns on
spontaneously
The device is
The pump is not
not pressure-
pressure-tight
tight
DECLARATION OF EU COMPLIANCE
We,
Güde GmbH & Co. KG
Birkichstrasse 6
D-74549 Wolpertshausen
Remedy
Germany
Plug the device into
hereby declare that the concept and construction of the
the grid
below-mentioned devices in versions which we market
comply with the respective elementary requirements
Use another socket
established by EU guidelines on safety and hygiene.
In case of device modifications which have not
Replace the fuse
been consulted with us, this declaration's validity
Try to use the
expires.
device without the
extension cord
Device labeling:
Replace the fuse
HIGH-PRESSURE CLEANER GHD 100
Check the network
HIGH-PRESSURE CLEANER GHD 140
voltage, it has to
HIGH-PRESSURE CLEANER GHD 180
correspond to the
type label
Object no.:
specifications
#86009
Connect to an
#86011
electric circuit which
#86013
is properly
protected with
Date/manufacturer's signature: 23.07.2010
respect to the high-
pressure cleaner
Signatory data:
performance
Clean the nozzle
Technical documentation:
Turn the high-
Respective EU guidelines:
pressure cleaner off
2006/42 EG
and let it run with
2004/108 EG
an open spray gun
2000/14 EG
and open water
2002/95 EG
faucet long enough
Applied harmonized standards:
to reach an even
EN 60335-1:2002+A1+A11+A12+A2+A13
effective pressure
EN 60335-2-79
Check whether the
EN 62233:2008
water supply
EN 55014-1:2006
connection
EN 61000-3-2:2006
corresponds to the
EN 61000-3-3:1995+A1+A2
technical
EN 61000-4-2:1997_A1
specifications. The
EN 61000-3-11:2000*
smallest water hose
Certification site:
allowed has the
TÜV Rheinland Product Safety GmbH
diameter of ½" or
Am Grauen Stein
Ø 13mm
D-51105 Köln
Clean the water
Germany
filter
Reference number:
Straighten the
S50172284 (#86009)
water hose
S50171416 (#86011)
Replace the nozzle
S50171424 (#86013)
Pull the trigger 5
times in a quick
* The device complies with the requirements established
succession
by EN 61000-3-11 and is subject to special connection
Connect to the
conditions. This means that the use on any, arbitrarily
water supply
chosen point is inadmissible. The device can cause, in
Clean the filter
unfavorable grid conditions, temporary fluctuations in
voltage. The device is intended exclusively for use on
connection points which do not exceed the maximum
Turn to an
permissible network impedance of Zmax = 0,233 Ω.
authorized
As the user, you have to make sure, if need be by an
specialist
agreement with your power supply company, that the
connection point which you want to use to power your
6 drops per minute
device complies with the stipulated requirement.
are acceptable. In
cases of abnormal
leakage, it is
necessary to
21
consult the problem
with a specialist