Stanley SG 5500 Traduction Des Instructions Originales page 15

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 64
The motor oil is best changed when the motor is at
working temperature.
- Only use motor oil (15W40/<0
- Place the generator on a slightly inclined surface so
that the oil drain plug is at the lower end.
- Open the oil drain plug (10) and let the hot engine oil
drain out into a drip tray.
- After the old oil has drained out, close the oil drain plug
and place the generator on a level surface again.
- Fill in engine oil up to the top mark on the oil dip stick.
- Important: Do not screw the dipstick in to check the oil
level, simply insert it up to the thread.
- Dispose of the waste oil properly.
8.5 Oil shortage cut-out
The oil shortage cut-out (11) responds if there is too little
oil in the engine. In this case it will not be possible to
start the engine or it will cut out automatically after a
short period of time. It cannot be started again until the
engine oil has been topped up (see point 8.4).
The unit is supplied in packaging to prevent its being
damaged in transit. This packaging is raw material and
can therefore be reused or can be returned to the raw
material system.
The unit and its accessories are made of various types
of material, such as metal and plastic. Defective
components must be disposed of as special waste. Ask
your dealer or your local council.
10. Transport
10. Transport
These requirements must be met:
crush hands and feet.
o
C: 5W30).
and 6.3)
handle (18)
15
G
G
B
B

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

E-sg 2200E-sg 4000Sg 2200Sg 3000Sg 4200

Table des Matières