TABLE "A" - PARAMETERS MENU - (PARA )
Parameter
min.
max.
5
300
OPEN WORK. T .
5
300
CLS WORK. T
0
180
TCA
TRF. L GHT.
1
180
CLR. T
1
240
output time
0
99
OP. D IST. S LOUD
(LEO B CBB DL2
(LEO B CBB DL2
0
99
CL. D IST. S LOUD
(LEO B CBB DL2
PARTIAL
10
50
OPENING
1
99
OP. F ORCE
1
99
CLS. F ORCE
1
99
OP. S LWD. F ORCE
CLS. S LWD.
1
99
FORCE
0
99
BRAKE
0
250
Maintenance
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
(**) Impact forces can be reduced by using deformable edges.
TABLE "B" - LOGICS
(LOGIC)
Logic
Definition
Automatic Closing
TCA
Time
Fast closing
FAST CLS.
INSTALLATION MANUAL
Default
Personal
Definition
Opening operation time [s]
300
Closing operation time [s]
300
Automatic closing time [s]
40
Time-to-clear traffic light
40
Activation time of the
10
timed output [s]
0
(LEO B CBB DL2
3 120 F02)
(LEO B CBB
DL2 3 120
Slow-down distance
F02 PHOT
during opening [%]
USA16)
30
3 230 L02)
0
3 120 F02)
(LEO B CBB DL2
Slow-down distance
3 120 F02 PHOT
USA16)
during closing [%]
30
3 230 L02)
Partial opening [%]
20
Leaf force during
75
opening [%]
Leaf force during closing
75
Leaf/leaves force during
opening during
75
slow-down
Leaf/leaves force during
closing during
75
slow-down [%]
Braking [%]
0
Programming number of
operations for
0
maintenance threshold
[in hundreds]
Cross out
Default
setting
used
0
0
1
0
0
1
Description
Maximum motor operation time, during opening.
Set the operation time so that it's slightly longer than the complete operating
cycle time. The value is changed by the Autoset cycle, adapting it to the opera-
tion time detected
Maximum motor operation time, during closing.
Set the operation time so that it's slightly longer than the complete operating
cycle time. The value is changed by the Autoset cycle, adapting it to the opera-
tion time detected
Waiting time before automatic closing.
Time-to-clear for the zone run through by traffic controlled by the traffic light.
zone [s]
Activation length of timed radio channel output in seconds
Slow-down distance for motor(s) during opening, given as a percentage of total travel.
The Autoset cycle changes the slow-down distance values if they don't allow at
least 50cm of travel at slowed speed.
W A R N I N G : O n c e t h e p a r a m e t e r h a s b e e n e d i t e d , a
co m p l e t e u n i n t e r r u p t e d o p e n i n g - c l o s i n g c yc l e i s r e q u i r e d.
WARNING: when the display reads "SET" , obstacle detection is not active.
Slow-down distance for motor(s) during closing, given as a percentage of total
travel. The Autoset cycle changes the slow-down distance values if they don't
allow at least 50cm of travel at slowed speed. WARNING: Once the parameter
has been edited, a complete uninterrupted opening-closing cycle is required.
WARNING: when the display reads "SET" , obstacle detection is not active.
Partial opening distance as a percentage of total opening following activation
of PED pedestrian command.
Force exerted by leaf/leaves during opening.
[if encoder = 0 or 1] the set force value represents the network voltage % that is
supplied by the board to the motor during the movement.
[if encoder = 2] This is the percentage of force delivered, beyond the force stored
during the autoset cycle (and subsequently updated), before an obstacle alarm
is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current
safety requirements are met with the set value (*). Install anti-
crush safety devices where necessary (**).
Force exerted by leaf/leaves during closing.
[if encoder = 0 or 1] the set force value represents the network voltage % that is
supplied by the board to the motor during the movement.
[if encoder = 2] This is the percentage of force delivered, beyond the force stored
during the autoset cycle (and subsequently updated), before an obstacle alarm
[%]
is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current
safety requirements are met with the set value (*). Install anti-
crush safety devices where necessary (**).
"Force exerted by leaf/leaves during opening at slow-down speed. "
[if encoder = 0 or 1] the set force value represents the network voltage % that is
supplied by the board to the motor during the movement.
[if encoder = 2] This is the percentage of force delivered, beyond the force
stored during the autoset cycle (and subsequently updated), before an obstacle
alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current
safety requirements are met with the set value (*). Install anti-
crush safety devices where necessary (**).
"Force exerted by leaf/leaves during closing at slow-down speed. "
[if encoder = 0 or 1] the set force value represents the network voltage % that is
supplied by the board to the motor during the movement.
[if encoder = 2] This is the percentage of force delivered, beyond the force
stored during the autoset cycle (and subsequently updated), before an obstacle
alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current
safety requirements are met with the set value (*). Install anti-
crush safety devices where necessary (**).
Percentage of braking applied to stop motion of motor(s).
Allows you to set a number of operations after which the need for maintenance
will be reported on the AUX output configured as Maintenance or Flashing
Light and Maintenance .
Logic not enabled
Switches automatic closing on
Logic not enabled
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
LEO B CBB DL2 3 230 L02-LEO B CBB DL2 3 120
Optional extras
F02-LEO B CBB DL2 3 120 F02 PHOT USA16
37
-