  • Page 1 Voorraadvat Storage tank Ballons de stockage ST 400/500/600/750/1000 Installatie-, Gebruikers- en Servicehandleiding Installation, User and Service Manual Manuel d'installation, d'utilisation et d'entretien...
  • Page 2 Gegevens onderhevig aan verandering. / Data is subject to change. / Données sujettes à révision. A.O. Smith Hoofdkantoor Europa De Run 5305 T : +31 (0)40 294 2500 Postbus 70 T : 0800 267 6484 (gratis) 5500 AB Veldhoven info@aosmith.nl Nederland www.aosmith.nl A.O.
  • Page 3 / Table des matières Deze handleiding bestaat uit 3 talen. 1 - NL Handleiding ST 400 t/m 1000 ..................5 2 - EN Manual ST 400 trough 1000 ................... 21 3 - FR Notice ST 400 à 1000 ..................... 37 This manual consists of 3 languages.
  • Page 4 Installatie-, Service- en Gebruikershandleiding...
  • Page 5 Lees deze handleiding Waarschuwing zorgvuldig Lees deze handleiding zorgvuldig voordat u het toestel in gebruik neemt. Het niet lezen van deze handleiding en het niet opvolgen van de instructies in deze handleiding kan leiden tot ongevallen en schade aan personen en het toestel. Copyright ©...
  • Page 6 Installatie-, Service- en Gebruikershandleiding...
  • Page 7: Table Des Matières

    Inhoudsopgave Technische specificaties ..................9 Vloerbelasting ......................9 Watersamenstelling ....................9 Werkruimte ........................ 9 Verpakking ........................ 9 Afvoeren ........................9 Algemene gegevens ....................10 Afmetingen ......................10 Installatie ....................... 13 Aansluitschema ....................... 13 Wateraansluitingen ....................13 Vullen en Aftappen ....................15 Vullen ........................
  • Page 8 Installatie-, Service- en Gebruikershandleiding...
  • Page 9: Technische Specificaties

    Technische specificaties 1.1 Vloerbelasting Houd in verband met het gewicht van het toestel rekening met de maximale vloerbelasting, zie de tabel (1.6 "Algemene gegevens"). 1.2 Watersamenstelling Het toestel is bedoeld om drinkwater op te warmen. Het drinkwater moet voldoen aan de regelgeving voor drinkwater voor menselijke consumptie.
  • Page 10: Algemene Gegevens

    1.6 Algemene gegevens Algemene gegevens Eenheid ST 400 ST 500 ST 600 ST 750 ST 1000 Inhoud 1055 Ledig gewicht Maximale vloerbelasting 1317 Energie-efficiëntieklasse (Energie Label) Stilstandsverlies Maximale werkdruk tank kPa (bar) 1000 (10) 1000 (10) 1000 (10) 1000 (10)
  • Page 11 Vooraanzicht doorsnede toestel IMD-1294 R0.0 0312731_ST_400-1000_NLENFR_V4.0, 2019-03-08...
  • Page 12 Installatie-, Service- en Gebruikershandleiding...
  • Page 13: Installatie

    Installatie 2.1 Aansluitschema De figuur geeft het aansluitschema weer. Dit schema wordt gebruikt in de paragrafen waarin het eigenlijke aansluiten wordt beschreven. Installatie Schema Legenda 2. inlaatcombinatie (verplicht) 3. T&P-ventiel (aanbevolen) 4. afsluiter (aanbevolen) 5. terugslagklep (verplicht) 6. circulatiepomp (optioneel) A.
  • Page 14 Let op Een inlaatcombinatie is verplicht. Monteer deze zo dicht mogelijk bij het toestel. Waarschuwing Tussen inlaatcombinatie en het toestel mag nooit een afsluiter of terugslagklep geplaatst worden. 2.2.2 Warmwaterzijdig Zie (B) in het aansluitschema (2.1 "Aansluitschema"). Opmerking Isolatie van lange warmwaterleidingen voorkomt onnodig energieverlies. 1.
  • Page 15: Vullen En Aftappen

    Vullen en aftappen Installatie Schema Legenda 2. inlaatcombinatie (verplicht) 3. T&P-ventiel (aanbevolen) 4. afsluiter (aanbevolen) 5. terugslagklep (verplicht) 6. circulatiepomp (optioneel) A. koudwatertoevoer B. warmwaterafvoer C. circulatieleiding IMD-0545 R2.0 3.1 Vullen Om het toestel te vullen gaat u als volgt te werk: 1.
  • Page 16: Aftappen

    1. Sluit de afsluiter in de warmwaterleiding. 3.2 Aftappen 2. Sluit de toevoerkraan van de inlaatcombinatie (2). 3. Open de aftapkraan. 4. Belucht het toestel (of installatie) zodat het helemaal kan leeglopen. Installatie-, Service- en Gebruikershandleiding...
  • Page 17: Onderhoud

    Onderhoud Let op Onderhoud mag alleen door een erkend service- en onderhoudsmonteur worden uitgevoerd. Bij elke onderhoudsbeurt dient het voorraadvat waterzijdig onderhouden te worden. Het onderhoud dient in de volgende volgorde te worden uitgevoerd. 1. Onderhoud voorbereiden 2. Waterzijdig onderhoud 3.
  • Page 18 Werkvolgorde: 1. Draai de bouten van de reiningsopening los. 2. Verwijder de deksel en de pakking. 3. Inspecteer de tank en verwijder de losse kalkaanslag en verontreinigingen. 4. Indien de kalkaanslag niet handmatig verwijderd kan worden, dient ontkalkt te worden met een ontkalkingmiddel. Neem contact op met de leverancier/fabrikant voor een advies over het te gebruiken ontkalkingmiddel.
  • Page 19: Garantie

    Garantie 5.1 Garantie algemeen Indien binnen één jaar na de oorspronkelijke installatiedatum van een door A.O. Smith geleverd voorraadvat, na onderzoek en ter uitsluitende beoordeling van A.O. Smith, blijkt dat een deel of onderdeel, met uitzondering van de tank, niet of niet juist functioneert ten gevolge van fabricage- en/of materiaalfouten, zal A.O.
  • Page 20: Uitsluitingen

    5.4 Uitsluitingen De in artikel 1 en 2 bedoelde garantie geldt niet: a. indien het voorraadvat door een van buiten komende oorzaak is beschadigd; b. in geval van misbruik, verwaarlozing (met inbegrip van bevriezing), verandering, onjuist en/of afwijkend gebruik van het voorraadvat en wanneer gepoogd is lekken te repareren;...
  • Page 21 Read this manual Warning carefully Read this manual carefully before starting the storage tank. Failure to read the manual and to follow the printed instructions may lead to personal injury and damage to the storage tank. Copyright © 2018 A.O. Smith Water Products Company All rights reserved.
  • Page 22 Installation, Service and User Manual...
  • Page 23 Table of contents Technical specifications ..................25 Floor load ........................ 25 Water composition ....................25 Working clearance ....................25 Packaging ....................... 25 Disposal ........................25 General specifications ..................... 26 Dimensions ......................26 Installation ......................28 Installation diagram ....................28 Water connections ....................28 Filling and Draining ....................
  • Page 24 Installation, Service and User Manual...
  • Page 25: Technical Specifications

    Technical specifications 1.1 Floor load Allow for the storage tank's weight and the maximum floor load; refer to the table (1.6 "General specifications"). 1.2 Water composition The storage tank is intended for heating drinking water. The drinking water must comply with the regulations governing drinking water for human consumption. The table gives an overview of the specifications.
  • Page 26: General Specifications

    1.6 General specifications General specifications Unit ST 400 ST 500 ST 600 ST 750 ST 1000 Contents litres 1055 Empty weight Maximum floor load 1317 Energy Efficiency Class (Energy Label) Heat Loss Max. operating pressure tank kPa (bar) 1000 (10)
  • Page 27 Front sectional view of the appliance IMD-1294 R0.0 0312731_ST_400-1000_NLENFR_V4.0, 2019-03-08...
  • Page 28 Installation, Service and User Manual...
  • Page 29: Installation

    Installation 2.1 Installation diagram This figure shows the installation diagram. This diagram is referred to in the sections describing the actual connection procedure. Note These products can be installed as vented and unvented. This manual only discusses unvented installations. For information about vented installations please contact A.O.
  • Page 30 2.2.2 Hot Water side See (B) in the installation diagram (2.1 "Installation diagram"). Note Insulating long hot water pipes prevents unnecessary energy loss. Optional: fit a temperature gauge (12) so you can check the temperature of the tap water. Fit the T&P valve (3). Fit a stop valve (11) in the hot water outlet pipe for servicing.
  • Page 31: Filling And Draining

    Filling and draining Note These products can be installed as vented and unvented. This manual only discusses unvented installations. For information about vented installations please contact A.O. Smith. Installation Diagram Legend 1. pressure relief valve (mandatory if mains water pressure is too high) 3.
  • Page 32: Draining

    3.2 Draining 1. Close the stop valve (4) between the cold water head tank and the cold water inlet (A). 2. Open the drain valve (9). 3. Bleed the water heater (or installation) so that it drains completely. Installation, Service and User Manual...
  • Page 33: Maintenance

    Maintenance Warning Maintenance may only be carried out by a competent person. At each service, the storage tank undergoes maintenance on water side. The maintenance must be carried out in the following order. 1. Preparation for maintenance 2. Water-side maintenance 3.
  • Page 34 Work order: 1. Undo bolts from the cover. 2. Remove cover and the gasket. 3. Inspect the tank and remove the loose scale deposits and contamination. 4. If the scale cannot be removed by hand, descale the storage tank with a descaling agent.
  • Page 35: Warranty

    Warranty 5.1 General warranty If within one year of the original installation date of a storage tank supplied by A.O. Smith, following verification, and at the sole discretion of A.O. Smith, an assembly or part (with exclusion of the tank) proves to be defective or fails to function correctly due to manufacturing and/or material defects, then A.O.
  • Page 36: Exclusions

    5.4 Exclusions The warranty set out in articles 1 and 2 will not apply in the event of: a. damage to the storage tank caused by an external factor; b. misuse, neglect (including frost damage), modification, incorrect and/or unauthorised use of the storage tank and any attempt to repair leaks; c.
  • Page 37 Veuillez lire attentivement ce Attention manuel Lisez attentivement ce manuel d'instructions avant de mettre l'appareil en service. Ce manuel d'instructions doit être lu scrupuleusement et les instructions de ce manuel d'instructions doivent être suivies sous peine d'accidents et de dégâts matériels et/ou de blessures corporelles.
  • Page 38 Notice d’installation, Mode d’emploi, Notice d’entretien...
  • Page 39 Table des matières Spécifications techniques ..................41 Charge maximale au sol l'appareil ................41 Composition de l'eau ....................41 Espace de travail ....................41 Emballage ....................... 41 Élimination ......................41 Données générales ....................42 Dimensions ......................42 Installation ......................43 Schéma de raccordement ..................
  • Page 40 Notice d’installation, Mode d’emploi, Notice d’entretien...
  • Page 41: Spécifications Techniques

    Spécifications techniques 1.1 Charge maximale au Tenez compte de la charge maximale exercée sur le sol par le poids de l'appareil, sol de l'appareil voir le tableau (1.6 "Données générales"). 1.2 Composition de l'eau L'appareil est destiné à réchauffer de l'eau potable. L'eau potable doit être conforme aux régulations d'eau potable pour la consommation humaine.
  • Page 42: Données Générales

    1.6 Données générales Données générales Unité ST 400 ST 500 ST 600 ST 750 ST 1000 Capacité 1055 Poids à vide Charge maximale au sol de l'appareil 1317 Class Efficacité Énergétique (Étiquette d’Énergie) Consommation d’entretien Pres. de fonctionnement max. du cuve...
  • Page 43 Vue de frontale des appareils IMD-1294 R0.0 0312731_ST_400-1000_NLENFR_V4.0, 2019-03-08...
  • Page 44 Notice d’installation, Mode d’emploi, Notice d’entretien...
  • Page 45: Installation

    Installation 2.1 Schéma de raccor- Cette illustration représente le schéma de raccordement. Ce schéma est utilisé dans dement les paragraphes suivants contenant une description du raccordement proprement dit. Schéma de raccordement Légende 2. groupe de sécurité (obligatoire) 3. soupape thermique (recommandée) 4.
  • Page 46: Côte Eau Chaude

    Attention Un groupe de sécurité est obligatoire. Montez-le le plus près possible de l'appareil. Avertissement Entre la combinaison d'entrée et l'appareil, vous ne pouvez jamais monter de vanne d'arrêt ou de clapet anti-retour. 2.2.2 Côte eau chaude Voir (B) du schéma de raccordement (2.1 "Schéma de raccordement"). Note L'installation des longues conduites d'eau chaude évite les pertes énergétiques inutiles.
  • Page 47: Remplissage É Vidange

    Remplissage é Vidange Schéma de raccordement Légende 2. groupe de sécurité (obligatoire) 3. soupape thermique (recommandée) 4. vanne d'arrêt (recommandée) 5. clapet anti-retour (obligatoire) 6. circulateur de bouclage (option) A. alimentation en eau froide B. sortie d'eau chaude C. conduit de circulation bouclage ECS IMD-0545 R1.0 3.1 Remplissage...
  • Page 48: Vidange

    3.2 Vidange Fermez la vanne d'arrêt dans la conduite d'eau chaude. 1. Fermez le robinet d'arrivée du groupe de sécurité (2). 2. 10.Ouvrez le robinet de vidange. 3. Purgez l'appareil (ou l'installation) pour qu'il (elle) puisse se vider complètement. Notice d’installation, Mode d’emploi, Notice d’entretien...
  • Page 49: Effecteur L'entretien

    Effecteur l'entretien Attention L'entretien ne peut entré effectué que par un professionnel de la maintenance ou de l'entretien agréé. A chaque entretien, l'appareil doit être contrôlé côté eau et côté gaz. L'entretien doit s'effectuer dans l'ordre suivant. 1. Préparer l'entretien 2.
  • Page 50: Contrôle Des Anodes

    Ordre du travail: 1. Faites tourner les boulons de l’ouverture de nettoyage. 2. Éliminez le couvercle et le joint. 3. Inspectez le réservoir. Éliminez la couche de calcaire accumulée et les saletés. 4. Si la couche de calcaire ne peut être éliminée manuellement, il convient de retirer le calcaire avec un détartrant.
  • Page 51: Garantie

    Garantie 5.1 Garantie générale Si, durant l'année suivant la date initiale d'installation d'un chauffe-eau livré par A.O. Smith après examen par et sur l'appréciation exclusive de A.O. Smith toute partie ou pièce, à l'exception de la cuve, ne fonctionne pas ou ne fonctionne pas correctement suite à...
  • Page 52: Exclusions

    5.4 Exclusions La garantie visée dans les articles 1 et 2 ne couvre pas les cas suivants: a. si le chauffe-eau a subi des dégradation sous l'effet d'agents extérieurs; b. en cas de négligence (y compris exposition au gel), modification, usage incorrect et/ou abusif du chauffe-eau et lorsqu'on a essayé...