Defrosting the refrigerator cabinet :
The integral vapouriser is sealed in foam in the rear wall;
you may therefore notice a build-up of frost around the
rear area. This layer of frost will start melting when the
compressor is not working. Through a system of hoses,
the melt-water drains into the collection tray below the
compressor, where it will be absorbed into the surrounding
air. The unit does not therefore require de-frosting, but only
proper cleaning instead.
∙ To enable the melt-water to drain freely, always ensure
that the channel and discharge opening in the cabinet
are free of any blockage.
Energy saving tips
∙ The appliance should be set up in a well-ventilated, dry
room.
∙ Do not expose the appliance to direct sunlight, and do not
position it next to any heat sources (radiators, cookers
etc.). If this cannot be avoided, however, suitable insulation
must be installed between the heat source and the unit.
∙ Do not cover the ventilation openings and grilles, and
ensure sufficient air circulation behind the unit.
∙ The compressor (at the rear) should be cleaned at
regular intervals. Accumulated dust causes an increase
in energy consumption.
∙ Warm food should be allowed to cool down before it is
stored inside.
Problem
The appliance is not
working at all.
The temperature
inside the freezer
compartment is not low
enough.
The normal operating
sound changes or
becomes louder.
Water is collecting on
the bottom of the unit.
20
Possible cause and solution
∙ There is a power failure
∙ The main fuse has blown.
∙ The temperature control is set to '0'.
∙ The fuse in the wall socket (if applicable) has blown. This can be checked by connecting
another electrical device to the socket and checking for function.
∙ Too much food has been stored in the appliance.
∙ The doors are not properly closed.
∙ There is too much dust on the condenser.
∙ Insufficient ventilation: the unit is too close to a wall or other structure or object.
∙ The temperature control is set too low.
∙ Check for proper positioning (uneven floor?).
∙ Are any adjacent objects affected by the running of the cooling unit (i.e. causing them to
vibrate?)
∙ Are there any objects on top of the unit which might be vibrating?
The melt-water drain system is blocked. Remove the blockage and clean the system.
∙ To prevent an increased build-up of ice, do not leave
the doors of the unit open for too long when loading or
taking out food.
∙ Frequent de-frosting helps to save energy. For detailed
information on cleaning the appliance, please refer to
the section De-frosting and cleaning.
∙ Do not set a lower-than-necessary temperature. For
detailed information on the temperature settings, please
refer to the section Temperature control.
Trouble-shooting
Certain typical sounds can be heard when the appliance is
switched on. These sounds are:
∙ caused by
the electrical
motor within
the compressor
assembly; during
compressor start-up
the sound level will
be slightly higher for
a limited period of time.
∙ caused by the cooling agent flowing through the circuit.
The following table lists possible malfunctions and their
probable causes and solutions. In the event of operational
problems, check first whether a solution can be found using
this table. If the problem persists, disconnect the appliance
from the mains power and contact our Customer Service
Department.