Installation manual with technical data
1.0
Relationship to the authorities ................... 9
2.0
Technical data .............................................. 9
3.0
Installation ..................................................10
4.0
Service ...........................................................11
5.0
Optional equipment ...................................11
Figures/ Pictures ..................................................32
General use and maintenance manual
6.0
Safety precautions
7.0
Choice of fuel
8.0
Use
9.0
Maintenance
10.0
Operational problems - troubleshooting
Product:
On all our products there is a label
Jøtul
Room heater fired by solid fuel
indicating the serial number and year.
Write this number in the place indicated
Standard
:
Minimum distance to adjacent combustible materials:
Minimum distance to adjacent combustible materials:
Emission of CO in combustion products
in the installation instructions.
:
Flue gas temperature
:
Nominal heat output
:
Efficiency
:
Operation range
:
Fuel type
:
Operational type
:
Always quote this serial number when
The appliance can be used in a shared flue.
contacting your retailer or Jøtul.
Country
Classification
Certificate/
Approved by
standard
Norway
Klasse II
SP Sveriges Provnings- och
Sweden
SP
OGC
Forskningsinstitut AB
SP Swedish National
Testing and Research
EUR
Intermittent
EN
Institute
Follow user`s instructions. Use only recommended fuels.
Montage- und Bedienungsanleitung beachten.
Verwenden Sie nur empfohlenen Brennstoffen.
Respectez les consignes d'utilisation. Utilisez uniquement
les combustibles recommandés.
Serial no: Y-xxxx, Year: 200x
Manufacturer:
221546
Jøtul AS
POB 1441
N-1602 Fredrikstad
Norway
Serial no.
1.0 Relationship to the
authorities
Installation of a fireplace must be according to local codes and
regulations in each country.
those which refer to national and European standards, must be
observed when installing the product.
Both an installation manual with technical data and a manual
on general use and maintenance are enclosed with the product.
The installation can only be used after it has been inspected by
a qualified inspector.
A name plate of heat-resistant material is affixed to the
product. This contains information about identification and
documentation for the product.
2.0 Technical data
Material:
Material sideplates:
Finish:
Fuel:
Log length, max.:
Flue outlet:
Flue pipe dimension:
Approx. weight:
Optional extras:
Dimensions, distances:
Technical data according to EN 13240
Nominal heat output:
Flue gas mass flow:
Recommended chimney draught:
Efficiency:
CO emission (13% O
):
2
Flue gas temperature:
Operational type:
"Intermittent combustion" here means normal use of a stove.
That is to say, if you want to continue producing heat, you add
more fuel as soon as the previous load of wood has burnt down
to embers.
Wood consumption
Jøtul F 350 has a nominal heat output of 8,0 kW.
with nominal heat emission: Approx. 1,8 kg/h. Another important
factor for proper fuel consumption is that the logs are the correct
size. The size of the logs should be:
Kindling:
Length: 30 cm
Diameter: 2 - 5 cm
Amount per fire: 6 - 8 pieces
Firewood (split logs):
Length: Approx 30 cm
Diameter: Approx. 8 cm
Intervals for adding wood: Approximately every 45 minutes
Size of the fire: 2,0 kg
Amount per load: 3 pieces
Nominal heat emission is achieved when the ignition vent is
open approximately 50% and the air vent 20-25%.
ENGLISH
All local regulations, including
Cast iron
Cast iron or
soapstone (optional equipment)
Paint
Wood
35 cm
Top and rear
2
Ø150 mm, 177 cm
cross section
Stove: 170 kg,
Set of soapstone: 54 kg
Side plates in soapstone,
Top tile insoapstone, extra rear
heat shield
See fig.1
8,0 kW
9,0 g/s
12 Pa
75%@8,2 kW
0,08%
o
340
C
Intermittent
Use of wood,
9