Initial Set-Up

1. Read safety warnings before setting-up air compressor.

Location

In order to avoid damaging the air compressor, do not incline the air
Caution
compressor transversely or longitudinally more than 10º.
1. Place air compressor at least 30 cm away from obstacles that may prevent proper ventilation.
Do not place air compressor in an area:
 Where there is evidence of oil or gas leaks.
 Where flammable gas vapors or materials may be present.
Serious injury or death may occur if electrical sparks from motor and pressure
Warning
switch come in contact with flammable vapors, combustible dust, gases or
other combustible materials. When using the air compressor for spray
painting, place the air compressor as far away f rom the work area as possible,
using extra air hoses instead of extension cords.
 Where air temperatures fall below 0°C or exceed 40°C.
 Where extremely dirty air or water could be drawn into the air compressor.

Electrical

Improper connection of the equipment-grounding conductor can result in a
risk of shock or electrocution. Check with a qualified electrician or service
Danger
personnel if you are in doubt as to whether the outlet is properly grounded.
Do not use any type of adapter with this product. If repair or replacement of
the cord or plug is necessary, do not connect the grounding wire to either flat
blade terminal. The wire with insulation having an outer surface that is green
with or without yellow stripes is the grounding wire.
This product must be grounded. If there should be a malfunction or
breakdown, grounding provides a path of least resistance for electric current
Warning
to reduce the risk of electric shock. This product is equipped with a cord
having an equipment grounding conductor and a grounding type plug. The
plug must be plugged into an appropriate outlet that is properly installed and
grounded in accordance with all local codes and ordinances.
1. SENCO® DOES NOT RECOMMEND THE USE OF EXTENSION CORDS as this can create power
loss and overheating of the motor. Use of an additional air hose is recommended rather than an
extension cord. If use of an extension cord is unavoidable, it should be plugged into a GFCI found in
circuit boxes or protected receptacles.
When using an extension cord, observe the following:
Use only extension cords having an electrical rating not less than the rating of the product. Do not use
damaged extension cords. Examine extension cord before using and replace if damaged. Do not
abuse extension cord and do not yank on any cord to disconnect. Keep cord away from heat and
sharp edges. Always shut off the air compressor switch before removing the plug from the receptacle.

Preparation

Cable Length
Wire Gauge
Up to 8 meters
12
Up to 30 meters
10
Up to 50 meters
8
Up to 75 meters
6
10
AWG
AWG
AWG
AWG
GB