• When positioning the device in wet areas such as
laundries, bath rooms or the like, secure the de-
vice locally with an RCD (Residual Current protec-
tive Device) which complies with the appropriate
regulations.
• Ensure that extension cords are completely un-
rolled.
Notes regarding the dehumidifying capacity
The dehumidifying capacity depends on:
• the spatial composition of the room
• the room temperature
• the relative humidity
The higher the room temperature and relative
humidity, the higher the dehumidifying capacity.
For using in living rooms, a relative humidity of
approx. 50-60 % is sufficient. In store rooms and
archives, the humidity should not exceed approx.
50 %.
EN
Operating elements
No.
Operating element
11
Operation indicator light (red)
12
Mains switch:
"I": Device is switched on.
"0": Device is switched off.
13
Condensation tank full indicator light (orange)
14
Selector switch to choose the level of power:
"H": high fan speed
"L": low fan speed
15
Knob for selecting desired level of humidity:
"MIN": low humidity (up to 49 %)
"MAX": high humidity (up to 100 %)
Operating manual – Dehumidifier TTK 75 S
13
14
15
11
12
B - 6