CODE
POSSIBLE CAUSE
17
Carbon build-up in pump.
18
Detergent type oil being used in pump
19
Motor overload protection switch has tripped
20
Extension cord is wrong length or gauge
21
Loose electrical connections
22
Possible defective motor or starting capacitor
23
Paint spray on internal motor parts
24
Fuse blown, circuit breaker tripped
25
Tank pressure exceeds pressure switch cut-in pressure
26
Pressure release valve on pressure switch has not unloaded
head pressure
POSSIBLE SOLUTION
Contact a D
WALT factory service center or a D
e
authorized service center.
Drain oil and refill pump using DeWALT synthetic or SAE 40,
non-detergent air compressor oil.
See Motor Overload under Features.
Check for proper gauge wire and cord length. See Extension
Cords under Installation.
Contact a D
WALT factory service center or a D
e
authorized service center.
Contact a D
WALT factory service center or a D
e
authorized service center.
Contact a D
WALT factory service center or a D
e
rized service center. Do not operate the compressor in the
paint spray area. See flammable vapor warning.
1. Check fuse box for blown fuse and replace as necessary.
Reset circuit breaker. Do not use a fuse or circuit breaker
with higher rating than that specified for your particular
branch circuit.
2. Check for proper fuse. Use only a time delay fuse.
3. Check for low voltage conditions and/or proper extension cord.
4. Disconnect the other electrical appliances from circuit or
operate the compressor on its own branch circuit.
Motor will start automatically when tank pressure drops
below cut-in pressure of pressure switch.
Set the On/Off switch to OFF. If the valve does not open,
replace switch. Contact a D
D
WALT authorized service center.
e
22
WALT
e
WALT
e
WALT
e
WALT autho-
e
WALT factory service center or a
e