The device must be checked before each use in order to detect malfunctions
and / or damage caused by transport and / or storage.
During the inhalation must sit in an upright and relaxed position at a table
and not in an armchair, to avoid compressing the airways and therefore
compromising the effectiveness of the treatment.
It is recommended not to keep the device in your hands and / or to avoid
prolonged contact with the body of apparatus.
WARNING: Put the device on a flat and stable surface in order not to block
the cooling vents on the sides of the device.
Extract the power supply cable and insert the plug into the mains socket. It
is recommended to unwind the entire length of the power supply cable to
must be replaced contact the GIMA technical service;
prevent dangerous overheating. If the power supply cable is damage and
Open the nebulizer 2 by unscrewing the lid;
Pour the medicine prescribed by the doctor into the nebulizer;
Re-close the nebulizer, re-screwing the lid;
Connect air pipe 5 to the air exit well 4;
Connect the other end of the pipe to the connection in the lower part of the
nebulizer;.
Connect the desired accessory to the nebulizer: child mask or adult mask,
mouth-piece or nosepiece;
Ensure that the supplied air filter (6) is present;
Press switch 1 on position I to proceede with nebulization;.
On completing of nebulization, press the switch on position 0 and remove
the plug from the socket;
Wash the nebulizer and its accessories as indicated in the cleaning charter;.
Place the cable and accessories inside the box.
Always use the nebulizer facing upwards so that substances and / or medicines cannot escape from the nebulizer during the
normal use.
WARNING: The power supply cable plug is the element of separation from the electrical mains system: even if the units equipped
with a special on / off switch button, the power supply plug must be kept accessible once the device is in use so as to allow a
further method of disconnection from the mains supply system.
INSTRUCTION FOR USE
NEVER INHALE IN HORIZONTAL POSITION
NEVER BEND THE NEBULIZER OVER 60
15
1-
Air Tube
2-
Nebulizer Tank
3-
Nebulization Nozzle
4-
Nebulizer Top
5-
Mouthpiece
6-
Adult Mask
7-
Pediatric Mask
8-
Nosepiece
GB