Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
FOR YOUR SAFETY: Read these instructions carefully before operating the unit.
ENERGY SAVING TIPS
Features
Fresh Air Ventilation Switch
(open for Fan only operation,
available in DAC100EB2GDB
and DAC120EB2GDB only)
Installation Instructions
ELECTRIC SHOCK HAZARD
To avoid the possibility of personal
injury, disconnect power to the unit
before installing or servicing.
NOTE: Your Room Air Conditioner is
designed for easy installtion in a single or
double-hung window. This unit is NOT
designed for vertical (slider type) windows
and/or through-the-wall applications.
Your Danby appliance is designed to be highly efficient in energy
savings. Follow these recommendations for greater efficiency.
1) Select a thermostat setting that suits your comfort needs and leave at
that chosen setting.
2) The air filter is very efficient in removing airborne particles. Keep the air
filter clean at all times. (usually cleaned every 2 weeks depending on
indoor air quality).
3) Use drapes, curtains or shades to keep direct sunlight from penetrating
and heating the room, but do not allow drapes or curtains to obstruct
the air flow around the unit.
4) Start your air conditioner before the outdoor air becomes hot and
uncomfortable, to avoid an initial period of discomfort while the unit is
cooling off the room.
5) When outdoor temperatures are cool enough, use the FAN MODE only,
on HIGH, MED., or LOW setting. This circulates indoor air, providing some
cooling comfort, and utilizes less electricity than when operating on a cooling
setting.
Interior Air Outlet
Control Panel
Interior Air Inlet
TOOLS NEEDED FOR INSTALLATION:
•
Screwdrivers: Phillips and flat head.
•
Power Drill: 1/8" (3.2mm) diameter drill bit.
•
Pencil
•
Measuring Tape
•
Scissors
•
Carpenter's Level
NOTE: Save the shipping carton and packing materials for future storage
or transportation. From carton, remove the plastic bag containing the
installation hardware kit necessary for the installation of your air
conditioner. Please check the contents of hardware kit against the corre-
sponding model check list, prior to installation of the unit. See Fig. 1.
Because the compressor is located on the controls side of the unit
(left side), this side will be heavier and more awkward to manipu-
late. Inadequate support on control side of the unit can result in
personal injury and damage to your unit and property. Therefore, it
is recommended that you have someone assist you during the
installation of this unit.
CAUTION
3
Cabinet
Exterior
Air Inlet
Air FIlter