Maintenance and care
Lubricating drive shaft
Angle transmission
Checking the blade
Inspect the drive shaft (A) every 100 hours of use and replenish
grease if it is insufficient.
Use good quality lithium multi grease.
1.
Remove plug (B) from angle transmission (A).
2.
Add grease, if necessary, using low pressure pump.
Use good quality lithium multi grease.
Do not overfill housing.
3.
Reinstall plug.
Use only blade designated for this model by the manufacturer.
When a crack is noticed on the blade, do not use it but replace
with a new one.
Ensure that the blade is correctly fitted in accordance with the
instructions.
When the cutting blade becomes dull due to wear reverse it for
further use.
When chip or bend occurs on the blade, vibration will increase.
Replace with new one.
When filing the blade file 3 cutting edges evenly using a flat file
as shown in the illustration. Otherwise, the balance will be lost
and vibration will increase.
24
NOTE
NOTE