TABELLA "B" MENU LOGICHE (logic)
LOGIC
DEFINITION
Automatic closing time
TCA
Panic opening (battery)
antipanic
(LOGIC 83)*
ra blow
Hammer during opening
c. o p
Open in other direction
Inv. dir.
Configuration of safety input
SAFE 1.
SAFE 1
(Fig. Q1, Q2, Q3, Q4)
(Fig. R1, R2, R3, R4)
Configuration of safety input
SAFE 2.
SAFE 2
(Fig. Q1, Q2, Q3, Q4)
(Fig. R1, R2, R3, R4)
Configuration of safety input
SAFE 3.
SAFE 3
(Fig. Q1, Q2, Q3, Q4)
(Fig. R1, R2, R3, R4)
Configuration of safety input
SAFE 4.
SAFE 4
(Fig. Q1, Q2, Q3, Q4)
(Fig. R1, R2, R3, R4)
Multifunction input operating
ultifunc.
mode
input
Door state output
door
operating mode.
status
Locking device
type of
operating mode
loc
Fixed Code
fixed code
INSTALLATION MANUAL
Cross out
using
DEFAULT
setting
1
1
Automatic Closing ON/OFF (TCA and Clear Time)
0
1
0
Panic Feature ON/OFF (Section ANTI-PANIC FUNCTION)
0
1
0
Hammer ON/OFF during opening
0
Change this parameter if the opening direction needs to be changed. Fig. AJ
1
0
Standard operating mode. Fig. AJ
0
Input configured as active safety during opening.
0
Input configured as active safety during opening and check that the operation is
1
correct at the start of every procedure.
Input configured as active safety during closing.
2
0
Input configured as active safety during closing and check that the operation is
3
correct at the start of every procedure.
Input configured as active safety during opening with "detection zone".
4
Input configured as active safety during opening with "detection zone" and check
5
that the operation is correct at the start of every procedure.
0
Input configured as active safety during opening.
Input configured as active safety during opening and check that the operation is
1
correct at the start of every procedure.
Input configured as active safety during closing.
2
2
Input configured as active safety during closing and check that the operation is
3
correct at the start of every procedure.
Input configured as active safety during opening with "detection zone".
4
Input configured as active safety during opening with "detection zone" and check
5
that the operation is correct at the start of every procedure.
Input configured as active safety during opening.
0
Input configured as active safety during opening and check that the operation is
1
correct at the start of every procedure.
Input configured as active safety during closing.
2
0
Input configured as active safety during closing and check that the operation is
3
correct at the start of every procedure.
Input configured as active safety during opening with "detection zone".
4
Input configured as active safety during opening with "detection zone" and check
5
that the operation is correct at the start of every procedure.
Input configured as active safety during opening.
0
Input configured as active safety during opening and check that the operation is
1
correct at the start of every procedure.
Input configured as active safety during closing.
2
2
Input configured as active safety during closing and check that the operation is
3
correct at the start of every procedure.
Input configured as active safety during opening with "detection zone".
4
Input configured as active safety during opening with "detection zone" and check
5
that the operation is correct at the start of every procedure.
0
1
Multifunction type []- Set the multifunction input operating mode. (Par.
0
2
MULTIFUNCTION INPUT OPERATING MODE)
3
4
0
Door state output mode []. Sets the DOOR STATE output's operating mode
0
(Sect. DOOR STATUS OUTPUT OPERATION MODE)
1
0
1
2
3
Lock mode []. Sets the locking device's operating mode
1
4
(Sect. LOCKING DEVICE OPERATION MODE)
5
6
7
8
1
ON:
Receiver is configured for operation in fixed-code mode.
0
OFF: Receiver is configured for operation in rolling-code mode.
0
DESCRIPTION
VISTA TL (ARIA-EVO)
- 25