Failure: The Wavebox pump does not operate
when
the
photo-electric
connected.
Cause: The photo-electric cell is located outside
of the illumination beam or is not illuminated
sufficiently.
Remedy: Chose a new position for the photo-
electric cell and re-attach (cf. Wavecontroller
6091).
Failure: The Wavebox is not operational; pump
is not operational.
Cause:
The
pump
mechanically.
Remedy: Disassemble the pump (cf. chapter titled
"Annual servicing"); remove any foreign bodies
or clean the pump drive unit (cf. chapter titled
"Disassembly of the drive unit"), and replace, if
and when required.
cell
has
been
has
been
blocked
Disfonctionnements: La Wavebox ne pulse pas
lorsque la cellule photo est raccordée.
Raisons: La cellule photo se retrouve en dehors du
cône de lumière ou n'est pas assez éclairée.
Solutions: Choisissez un nouvel emplacement
ou re-fixez la cellule photo (voir Wavecontroller
6091).
Disfonctionnements: La Wavebox ne fonctionne
pas, pompe hors service.
Raisons: La pompe est bloquée mécaniquement.
Solutions: Démontez la pompe (voir Entretien
annuel), extrayez le corps étranger ou nettoyez
l'entrainement de la pompe (voir Démontage de
la pompe), remplacez si nécessaire.
89