Control Panel Indicators
The following is a description of the control panel indicators.
Motor
Running
Indicator
RAPID
CLEAN
Pressure Indicator
The pressure indicator shows the current operating pressure of the
sprayer. It has three different indications: blinking yellow, solid
yellow, and solid green.
Blinking Yellow
When the pressure indicator is blinking yellow, the sprayer is
operating between 0 and 200 PSI. A blinking yellow pressure
indicator means:
• The sprayer is plugged in and turned "ON"
• The sprayer is at priming pressure (little or no pressure)
• It is safe to move the PRIME/SPRAY valve between positions
• It is safe to change or replace the spray tip
NOTE: If the pressure indicator begins blinking yellow
when the pressure control knob is set at a higher
pressure and the PRIME/SPRAY valve is in the
SPRAY position, either the spray tip is worn or the
sprayer is in need of service/repair.
Solid Yellow
When the pressure indicator is solid yellow, the sprayer is operating
between 201 and 1900 PSI. A solid yellow pressure indicator means:
• The sprayer is at the proper pressure setting for spraying stain,
lacquer, varnish, and multi-colors
• If the pressure indicator goes to solid yellow when the
pressure is set so that it starts at solid green, it indicates one of
the following:
a.
Tip Wear Indicator — when spraying with latex or at high
pressure the solid yellow appears. This means the tip is worn
and needs to be replaced.
b.
Tip Too Large — when a tip that is too large for the sprayer is
put in the gun, the pressure indicator will turn from solid green
to solid yellow.
c.
Fluid Section Wear — if a solid yellow pressure indicator
appears when using a new tip and the pressure is set at
maximum, service may be required (worn packings, worn
piston, stuck valve, etc...).
Solid Green
When the pressure indicator is solid green, the sprayer is operating
between 1901 and 3300 PSI. A solid green pressure indicator means:
• The sprayer is at the proper pressure setting for spraying oil-
based and latex house paints
• The sprayer is operating at peak performance at a high
pressure setting
Motor Running Indicator
The Motor Running indicator is on when the motor is commanded to
run. This indicator is used by service centers to troubleshoot motor
problems.
NOTE: If the motor running and pressure indicators blink
alternately, it means the motor has overheated. Turn
pump OFF and allow to cool.
English
Pressure Relief Procedure
Pressure
Indicator
1. Lock the gun by pushing the gun trigger lock to the locked
position.
2. Turn off the sprayer by moving the ON/OFF switch to the OFF
position.
3. Turn the pressure control knob counterclockwise to its OFF
position in the black zone.
4. Unlock the gun by pushing the gun trigger lock to the
unlocked position.
5. Hold the metal part of the gun firmly to
the side of a metal container to ground
the gun and avoid a build up of static
electricity.
6. Trigger the gun to remove any pressure
that may still be in the hose.
7. Lock the gun by pushing the gun trigger lock
to the locked position.
8. Move the PRIME/SPRAY valve down to the
PRIME position.
6
Be sure to follow the pressure relief procedure when
shutting down the sprayer for any purpose, including
servicing or adjusting any part of the spray system,
changing or cleaning spray tips, or preparing for
cleanup.
© Titan Tool Inc. All rights reserved.