4. Screw the gas pressure regulator/hose assembly to the 20 lb
LP gas fuel tank as shown.
A
A. 20 lb LP gas fuel tank
B. Gas pressure regulator/hose assembly
5. Turn on the gas supply. Wait a few minutes for gas to move
through the gas line.
6. Test all connections by brushing on an approved
noncorrosive leak-detection solution. Bubbles will show a
leak. Correct any leak found.
7. Go to "Check and Adjust the Burners" section.
If Converted to Natural Gas
WARNING
Explosion Hazard
Use a new CSA International approved "outdoor"
gas supply line.
Securely tighten all gas connections.
Failure to do so can result in death, explosion, or fire.
This installation must conform with local codes and ordinances.
In the absence of local codes, installations must conform with
either the National Fuel Gas Code ANSI Z223.1, or CAN/CGA-
B149.1 Natural Gas and Propane installation code.
Copies of the standards listed above may be obtained from:
CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
1. Make gas connections.
A combination of pipe fittings must be used to connect the
grill to the existing gas line.
If local codes permit, use an outdoor flexible stainless
steel tubing gas connector, design-certified by CSA
International, to connect the grill to the rigid gas supply
line. A ⁵⁄₈" diameter line is recommended. Using a wrench
to tighten, connect the gas supply to the grill. Use pipe-
joint compound on all non-flared male threads. Do not
kink or damage the flexible connector when moving the
grill.
14
B
2. Open the manual shutoff valve in the gas supply line. The
3. Test all connections by brushing on an approved
4. Go to "Check and Adjust the Burners" section.
Plug in Grill
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
1. Plug into a grounded 3-prong outlet.
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
Pipe-joint compounds suitable for use with Natural gas
must be used. Do not use TEFLON
A
C
D
A. Grill gas pipe
B. New ANSI Z21.54 certified gray hose
C. Rear of grill
D. To Natural gas supply
valve is open when the handle is parallel to the gas pipe.
A
A. Closed valve
B. Open valve
noncorrosive leak-detection solution. Bubbles will show a
leak. Correct any leak found.
WARNING
Electrical Shock Hazard
®†
tape.
B
B