Safety instructions, Starting operation
Regularly check the hose clamp for tight fit.
Check outlet tube and seal for tight fit. If necessary,
tighten again outlet tube and/or replace seal.
When using a hand nozzle with an attached key button,
only use the key button with a safety extra-low voltage.
Generally replace a defect signalling cable.
Only use the hand nozzle with safety handle.
Non-compliance with the safety instructions may cause
injuries to the operator, pollution of the environment or
damage to the hand nozzle.
Starting operation
Ensure that the supply voltage corresponds with
the voltage indicated on the name plate.
Never operate the pump unless the union nut between
motor and pump has been firmly tightened.
Immerse the pump vertically into the liquid and secure it in a
vertical position by the use of a barrel fitting or a screw clamp.
Always check power supply cable for damage
before starting operation.
Keep solvents away from the power supply cable.
Only switch the motor on when the pump is in the liquid.
Before inserting the plug to the socket, ensure that
on/off-switch is set to "0" (Stop).
Insert the plug.
Switch on the motor.
Cleaning ater operation, Measures after use, Dismantling and Disposal
Cleaning after each operation
Clean the pump by flushing an appropriate cleaning agent.
First pump the cleaning agent in circuit, then rinse with
clean detergent.
Do not remove motor from the pump as long as there is
any back pressure.
Before removing the motor from the pump, completely
drain pump, flexible hose and hand nozzle.
Do not use flammable liquids to clean the pump.
The pump and hose must be compatible with
the cleaning agent.
The pump should not be immersed deeper into
the cleaning agent than the outlet connection.
Dismantling of pump for cleaning :
1. Remove the plug.
1. Release union nut between motor and pump.
2. Remove the motor.
3. Remove inner tube from the pump.
Measures after use
Attention!
Empty pump, hose and fittings after every use.
Drain hand nozzle after use. Otherwise liquid being
contained within the outlet tube will flow out without control.
Dismantling and Disposal
Pump, hose and fittings must be emptied prior to dismantling.
Prior to dismantling the outlet tube switch the pump off and
disconnect the mains.
Collect environmentally harmful substances and liquids in
appropriate containers and dispose of them in an environmen-
tally sound manner.
Dispose of scrap material and parts that cannot be repaired or
reused in an environmentally sound manner.
16
17