Testing / Repair
Testing / Repair
 Regulary check the pump according to the relevant national
safety instruction and/or rules for prevention of accidents
(in Germany these are e.g. BGV A3).
 Repairs should only be carried out by the manufacturer
or an authorized repair shop.
Note
 Depressurise the system.
Separate pump from current.
Empty hose and hand nozzle.
 Always replace defective parts.
Only use genuine spare parts.
 There must be at least 6 balls in the swivel joint.
Replacement of hose connector and / or seal:
1. Take off the safety lever (screw out safety screw)
2. Take out the balls off the swivel joint (maybe with the help of a
magnet pin)
Ball
Seal
Hose connector
Safety screw
Safety lever
Technical data
Technical data
Part number
Pump type
Delivery rate *)
Pressure head max.
Viscosity max.
Temperature fluid
Density max. fluid
Immersion length
Pump pipe diameter
Materials in contact with fluid
Pump housing
Shaft
Impellor
Mechanical seal
Seal
Hose
Tap
Hose connection
Hose clip
Barrel connector
Power motor
protected to
Voltage
Rated current
No-volt release
Overload protection switch
Speed control
Cable
Colour motor
Colour top of motor
Weight
Dimensions (HxWxD)
*) hose and hand nozzle adapted, water at 25°C
**) at 60 Hz the capacity is reduced by approx. 8 %
18
19
1023087
®
DULCO
Trans 50/1200 PP
4800 l/h
12,4 m
< 500 mPas
< 50°C
< 1,8 kg/dm³
1200 mm
50 mm
PP, Hastelloy C, ETFE, NBR, ceramic
oxide/PTFE/carbon, FKM, PVC, PE
PP (Polypropylene)
Hastelloy C
ETFE
ceramic oxide/PTFE/carbon
FKM
PVC with steel helix 3 m, DN 25
PP, DN 25, RAL 2003
DN 25 for hose 25/34 mm
2 pieces, stainless steel 1.4301
PP, G 2 A
800 W
IP 24
230 VAC; 1~; 50 Hz / 60 Hz**)
3,8 A
with
with
without
5 m, with Euro plug
RAL 2003 (orange)
RAL 5003 (blue)
7,4 kg
1489 x 217 x 115 mm

Publicité