This manual shall be used in conjunction with the Alarm Controller PowerSeries panel manual; all the safety
instructions specified within that manual (or equivalent) shall be observed. The PowerSeries panel is refer-
enced as "panel" throughout this document.
The IT-230 Interface shall be installed in the location specified in these instructions. The equipment enclosure
must be fully assembled and closed, with all the necessary screws/tabs, and secured to a wall before opera-
tion. Internal wiring must be routed in a manner that prevents:
•
Excessive strain on wire and on terminal connections,
•
Interference between power limited and non power limited wiring,
•
Loosening of terminal connections, and
•
Damage of conductor insulation.
WARNING: Never install this equipment during a lightning storm!
Safety Information
External wiring must be protected and routed in a such a way that all the local, state, federal electrical code
and regulations and fire codes are fully met; the external wiring shall pose no risks for an operator. The external
wiring shall be clearly labeled at both ends. Where required, notify the local authorities in regard to the per-
formed wiring.
The Installer must instruct the System user on each of the following:
•
Do not attempt to service this product. Opening or removing covers may expose the user to dangerous
voltages or other risks.
•
Any servicing shall be referred to trained service personnel only.
•
Use authorized accessories only with this equipment.
Model Information
IT-230: Is an RS-422 Interface that allows two way message transfer between DSC PC1616/PC1832/PC1864
Power Series Panel and C24-HUB. The IT-230 provides C24 Interactive monitoring and control via an
RS-422 balanced line link to the C24-HUB. The link speed is 115.2 KB and is programmable by the installer.
NOTE: The C24-HUB is an interface device which connects to security panels, IP cameras, sensors,
Z-wave based home automation devices, etc. to deliver a host of advanced functionality. Lifestyle
events are defined as "non alarm" events. Life-safety events are defined as "alarm" events.
Features
• Full event reporting to central station and C24 Interactive, via RS-422 to C24-HUB.
• Programmable Labels.
• RS-422 balanced line communication to external C24-HUB up to 1,000 ft. (305 m).
• Buffers 1,000 date and time stamped Life Style events to C24-HUB as First In First Out (FIFO) messages.
Technical Specifications
The input voltage to the IT-230 Interface can be drawn from the Underwriters Laboratories/Underwriters Labo-
ratories Canada (UL/ULC) listed control panel or provided by an external UL/ULC listed power supply rated for
the application (external power-limited source).
NOTE: The power supply must be Class II, Power Limited.
Ratings
Model
POWER SUPPLY RATINGS
Input Voltage
CURRENT CONSUMPTION
Standby Current
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
Humidity
MECHANICAL SPECIFICATIONS
Board Dimensions (mm)
Weight (grams)
Compatibility
Interface
NOTE: Enter [*][8][Installer Code] [900] at keypad to view the Power panel version number.
Panel
IT-230
Power Series
GENERAL
IMPORTANT
Table 1: IT-230 Interface Module Ratings
IT-230 Interface Module
11.1~12.6 V
140mA @ 12 V
0°C - 49°C (32°F- 120°F)
5% ~ 93% relative humidity, non-condensing
150 × 50 × 15
45
Table 2: Compatible Power Panels
Description
• Power Series PC1616, version 4.5+
• Power Series PC1832, version 4.5+
• Power Series PC1864, version 4.5+
1
DC
DC