Technical Data
Welder GIS 140
Art. No ...............................................................................................................................................................................................20025
Service connection .......................................................................................................................................230 V ~ 50-60 Hz
Rated input voltage AC Voltage U
Protection ................................................................................................................................................................................ 16 A
Maximum rated input current I
Maximum effective input current I
Idle voltage U
...................................................................................................................................................................................85 V
0
Degree of protection ................................................................................................................................................................... IP 21S
Insulation class ........................................................................................................................................................................................ H
Welding current I
...........................................................................................................................................................................140 A
2
Operating voltage U
......................................................................................................................................................... 22,8-25,6 V
2
Material thickness ......................................................................................................................................................................1-7 mm
Regulated section .................................................................................................................................................... 20 A-140 A
Dimensions ......................................................................................................................................................... 282 x 119 x 178 mm
Weight .................................................................................................................................................................................... 5,5 kg
......................................................................................................................................................................................MMA
Switch-on timeX* ............................................................ ............................................140A~25% | 95A~60% | 70A~100%
Electrodes ...................................................................................................................................................................1,0-4,0 mm
* Actual working time and total working time ratio.
Switch-on time determined at 40°C using simulation
Read and understand the
operating instructions before
using the appliance. Abide by all
the safety measures stated in the service manual. Act
responsibly toward third parties.
In case of any doubts about connection and
operation refer please to our customer center
Specified Conditions Of Use
Welder in protective atmosphere for thermal connec-
tion of ferrous metals by melting edges and including
mixture Do not use this product in any other way as
stated for normal use. Not observing general regula-
tions in force and instructions from this manual does
not make the manufacturer liable for damages.
Ambient temperature -10 °C - +40 °C
Relative air humidity max. 50 % (40 °C), 90% (20 °C)
Altitude above sea level max. 1000 m
The ambient environment must be free from
abnormal amounts of dust, acids, corrosive gases or
substances.
Please note that our equipment has not been
designed for commercial, craft or industrial use. If the
equipment is used in commercial, craft or industrial
operation or for similar activities, we cannot assume
any liability.
.......................................................................................................................................... 230 V
1
............................................................................................................................................. 27 A
1max
.....................................................................................................................................13,5 A
1eff
Safety instructions
WARNING! Electric shock! There is a risk of
an injury caused by electric shock!
Operation is only allowed with a safety
switch against stray current (RCD max. stray
current of 30mA).
IP21 protection degree of the welder. The welder
must not be exposed to rain and moisture when
being operated or stored.
Check the voltage. Technical data given on the type
label must correspond with electric network voltage.
Insert the plug of the electrical cable in a socket of
suitable shape, voltage and frequency complying
with current regulations.
Use extension cables with a maximum length of 5
meters and with a cable cross-section of not less than
1.5 mm2. Use of extension cables of different length
and cross-section and also of adapters and multiple
sockets should be avoided.
Check the cable and/or socket for damages before
the appliance putting into operation.
Defective cable or plug may cause electric shock.
Do not pull the service cable to pull the plug out of