Télécharger Imprimer la page

EINHELL NEW GENERATION NSG 230 F Mode D'emploi page 13

Masquer les pouces Voir aussi pour NEW GENERATION NSG 230 F:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15
Anleitung NSG 230 F_SPK1
max. 160 A
16 A
2 ~
Important!
The mains plug is designed only for a welding
current of max. 160 A. If you wish to operate your
machine with a higher welding current, the
assembled mains plug must be replaced by a
mains plug approved for 32 A.
Important!
The mains plug may only be replaced by a
trained electrician.
Please observe the following instructions in order to
avoid the risk of fire, electric shock or personal
injuries.
Never use the appliance with a rated voltage of
400 V if the appliance is set to 230 V. Caution:
Fire risk!
Please disconnect the appliance from the power
supply before setting the rated voltage.
Adjusting the rated voltage during operation of the
welding set is strictly prohibited.
Before operating the welding set, please ensure
that the rated voltage selected on the appliance
complies with that of the power source.
Note:
The welding unit is equipped with a 400 V ~ 16 A
CeCon plug. Use the supplied adapter cable No. 14
to operate the welding unit with 230 V~ .
7. Welding preparations
Connect the earth terminal (2) direct to the part to be
welded or to the support on which the part is resting.
Ensure that the earth terminal is in direct contact with
the part to be welded. You should therefore avoid
coated surfaces and/or insulated materials. The
electrode holder cable has a special clamp at one
end, which is used to secure the electrode. The
welding safety shield must be used at all times for
welding. It protects your eyes from the radiation
emitted by the arc and nevertheless enables you to
watch the welding process.
25.01.2006
13:53 Uhr
Seite 13
8. Welding
After you have made all the electrical connections for
the power supply and for the welding circuit, you can
proceed as follows:
Insert the unsheathed end of the electrode into the
electrode holder (1) and connect the earth terminal
(2) to the part you wish to weld.
Ensure that a good electric contact is made.
Switch on the welding set at the switch (4) and set
the welding current using the hand wheel (3) to suit
the electrode you wish to use.
Hold the safety shield in front of your face and rub
the tip of the electrode on the part you wish to weld
as if you were striking a match. This is the best
method of igniting the arc.
Check that you have the correct electrode and
current strength on a test part.
Electrode (Ø mm):
Welding current (A)
2
2,5
3,2
4
Important!
Do not dab the workpiece with the electrode since it
could be damaged, making it more difficult to ignite
the arc.
As soon as the arc has ignited, attempt to keep it a
distance from the workpiece equivalent to the
diameter of the electrode.
This distance should be kept as constant as possible
during the welding process. The angle of the
electrode in the direction in which you are working
should be 20/30°.
Important!
Always use tongs to remove spent electrodes and to
move parts that you have just welded. Please note
that the electrode holder (1) must always be put
down so that it is insulated after you have completed
the welding work.
Do not remove the slag until the weld has cooled.
If you want to continue a weld after an interruption,
the slag from your initial attempt must first be
removed.
GB
40 - 80 A
60 – 110 A
80 - 160 A
120 - 200 A
13

Publicité

loading

Ce manuel est également adapté pour:

New generation 15.440.7015.440.70