Troubleshooting Guide
Symptoms
Recommended Action
1.
Poor flush.
A.
Adjust the tank water level to match the waterline.
B.
Fully open the water supply shut-off valve.
C.
Clear obstructions from the trapway, jet, or bowl rim holes.
D.
Clear obstructions from the waste line.
2.
No flush.
A.
Reconnect the chain to the trip lever or flush valve.
B.
Adjust the chain assembly to remove excessive slack.
3.
The fill valve
A.
Adjust the chain for proper slack so the seal is not held off the
turns on/off
flush valve seat.
by itself
B.
Clean or replace the seal if it is worn, dirty, or misaligned with
without the
the flush valve seat, or if the flush valve seat is damaged.
toilet being
Replace the flush valve seal or flush valve.
flushed, or it
C.
Clean the fill valve seat and seat washer of debris, or replace
runs, allowing
the piston/seat washer assembly.
water to enter
the tank.
D.
Remove the tank and tighten the flush valve nut if flush valve
gasket is leaking. Do not overtighten. If leakage continues,
replace the gasket.
E.
Adjust the tank water level if it is too high.
F.
Replace the fill valve if the valve float sinks.
4.
Tank takes
A.
Fully open the water supply shut-off valve.
excessive time
to fill.
B.
Clean the valve inlet, valve head, or supply line. Flush the
lines.
5.
There is
A.
Partially close the water supply shut-off valve if the water
excessive noise
pressure to the toilet is too high. Check the toilet performance
when the tank
following any such adjustment.
is filling.
B.
Remove dirt or obstructions from the valve head. Flush the
lines.
Guide de dépannage
Symptômes
Action recommandée
Faible chasse.
Régler le niveau d'eau du réservoir au niveau du repère.
1.
A.
B.
Ouvrir complètement la valve d'arrêt d'alimentation.
Dégager toutes obstructions du siphon, du jet ou des trous du
C.
rebord de la cuvette.
D.
Dégager toute obstruction de la ligne d'évacuation.