4.Start the engines and make sure the Output indicators (green) come
ON.
5.Confirm that the appliance to be used is switched off, and plug in the
appliance.
6.Switch on the equipment to be used.
AC Circuit Protector (Except U type)
The AC circuit protector on the receptacle box for parallel operation will
automatically switch OFF (push button comes out) if there is a short
circuit or a significant overload of the generator at receptacle.
If an AC circuit protector switches OFF automatically, check that the
appliance is working properly and does not exceed the rated load
capacity (16 A) of the circuit before resetting the AC circuit protector
ON (pushing the push button in).
AC CIRCUIT
PROTECTOR
34
ON
OFF
OUTPUT INDICATOR
(GREEN)
RECEPTACLE BOX FOR
PARALLEL OPERATION