5.
Connect power tools (Fig. 22)
Connect in order of Hose id 1-1/2" × 4.9 ft
(id 38 mm × 1.5 m long) and Joint (C) (Optional
Accessory). Connection is done by pressing in
the direction of the arrow.
6.
Cloth fi lter cleaning
CAUTION
If the tank is fi lled with dusts, the suction power
declines. Dump dusts as early as possible
when they reach the half of the tank height.
When the suction power declines during use,
remove dusts in the following procedure:
NOTE
Since the cloth fi lter cleaning device operates
when the suction power declines to some
extent, it also operates in the following cases:
When the suction mouth at the tip of the hose is
closed.
When the hose is clogged with foreign matter.
To clean the cloth fi lter using a strong air fl ow:
18
Hose id 1-1/2" × 4.9 ft
(id 38 mm × 1.5 m long)
Joint (C)
Fig. 22
NOTE
Depending on the operating environment, the
main unit's temperature protective function
may activate and switch off the unit.
Should the unit switch off , refer to
"TROUBLESHOOTING GUIDE" (Page 24).
Dust collecter
Dust collection adapter
(Optional Accessory)
(1)
Pull out the zoom pipe on the tip of the hose.
(2)
Block off the tip of the hose with your hand and
turn the power switch ON. Next, press the dust
button on the top of the head for approximately
one second and release the button. Repeat
three times and the suction power should
recover. (Fig. 23)
If the suction power is not recovered, the tank
is almost fi lled with dusts. Dump dusts in the
tank.
PUSH
Dust button
Vacuum switch
Power tool
Power tool
Hose id 1-1/2" × 4.9 ft
(id 38 mm × 1.5 m long)
ON
Fig. 23

Publicité