English
(2)
Turn the USB power switch ON (Fig. 7)
When you turn the USB power switch ON, the
USB power indicator lamp will light up.
Rubber cover
USB cable
USB port
(3) Connect the USB cable. (Fig. 7)
Pull back the rubber cover and fi rmly plug in a
commercially available USB cable (appropriate
to the device being charged) into the USB port.
○
When the power cord is not plugged into an
outlet and the battery runs out of power, power
output will stop and the USB power indicator
lamp will shut off .
○
When the USB power indicator lamp goes out,
change the battery or plug the power cord into
an electrical outlet.
(4)
When charging is completed
○
The USB power indicator lamp will not go
out when a USB device has been completely
charged.
To verify charge status, check the USB device.
○
Turn the USB power switch OFF and unplug the
power cord from the electrical outlet. (Fig. 7)
○
Remove the battery from the charger and place
the rubber cover over the USB port.
BEFORE USE
Check the work area to make sure that it is clear of
debris and clutter.
Clear the area of unnecessary personnel. Ensure
that lighting and ventilation is adequate.
PRIOR TO OPERATION
WARNING
Before use, check the following. 1 to
2 should be checked before insert the
battery.
1.
Confi rm that the vacuum switch is OFF.
(Fig. 8)
If, without knowing that the vacuum switch is
ON, the battery is inserted, the appliance will
start suddenly, causing unexpected accidents.
14
USB power
switch
USB power
indicator lamp
Fig. 7
The vacuum switch will be turned on by pushing
"ON" and it will be turned off by returning it to
"OFF". Be sure to check that the vacuum switch
is OFF.
Vacuum switch
2.
Order of use for batteries
When two batteries are installed, the battery
with the least remaining power is used fi rst until
it is empty. Once empty, use is automatically
switched over to the other battery.
Use is still possible with a single installed battery.
NOTE
When there is no more remaining power in a
battery, immediately recharge the battery for
convenient use later.
3.
Check the fi lter
Referring to "3. Attaching Filters" the fi lter
should be correctly attached.
CAUTION
Water absorption amount will severely decline
if the standardly equipped cloth fi lter is
repeatedly used to absorb liquid.
Use the separately sold nylon fi lter when
repeatedly absorbing large amounts of water.
4.
Inserting the battery (Fig. 9)
As you pull on the clamp lever, open the battery
guard. Next, match the battery with the unit's
groove and fi rmly press the battery in until you
hear a click.
CAUTION
Do not touch the terminals. Doing so may result
in cutting your hand on the terminals or other
unexpected injury.
Battery guard
Clamp lever
OFF
Fig. 8
Insert
Battery
Groove
Terminal
Fig. 9