Test Run; Note To The Installer; Periodic Maintenance; Care & Cleaning - Toto EcoPower Manuel D'installation Et D'utilisation

Valve de chasse
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

After connecting the battery, the initialization process takes 5 minutes. After approximately 30
seconds, the sensor LED will start flashing in 4 second intervals until the initialization is
complete. Please wait before starting the Test Run.
1. For Toilet: Sit on the toilet seat.
For Urinal: Stand within two feet from the front of the Flush Valve.
2. Stay there for 6 seconds or more and then leave the toilet seat or the urinal. The valve
should automatically flush, immediately for urinals and after 3 seconds for toilets.
3. Press the manual flushing button for 2 seconds and make sure the valve flushes properly
and the sensor red light of the sensor is on.
adjust the control stop clockwise.
4. Recheck all the pipe connections for water leaks. If the Flush Valve is not operating
properly following the test run consult the Troubleshooting section on p.12.
After the Flush Valve unit has been installed correctly, please explain to your customer how to
use it and tell them to observe the following instructions:
1. Do not put any object in front of the sensor window which could obstruct the sensor,
causing it to malfunction.
2. In case of any trouble, consult the troubleshooting section on p.12. If you lack the necessary
skills required or have difficulty following the directions for installation, maintenance, repairs,
troubleshooting or adjustments of the product, do not proceed without help from a qualified
person to assist you.
Please check your EcoPower Flush Valve at least once a month according to the following
instructions to avoid risk of property damage.
Check the piping to see whether there is any leakage.
Press the manual flushing button and make sure the
sensor red light is on for 2 seconds to see if the genera-
tor performs properly or not.
If the red light is not on, check the generator to see if
any debris is clogged up at the turbine.
IMPORTANT! Do not scratch the sensor or faceplate when cleaning.
 Avoid using any cleaning materials that may scratch the surface.
 Never use polishing powder, detergent that includes coarse particles, thinners, benzene,
acids, alkaline detergents, or nylon scrub brushes.
 To safely clean the surface, wipe it using a dampened soft cloth with diluted dishwashing
detergent and dry it with another soft cloth. If this does not adequately clean the surface,
wipe the area with a neutral detergent and wet cloth.

TEST RUN

To correct overflow from a urinal Flush Valve,

NOTE TO THE INSTALLER

PERIODIC MAINTENANCE

CARE & CLEANING
10