At Commands - ADEUNIS Sigfox RC1 ANALOG Guide Utilisateur

Masquer les pouces Voir aussi pour Sigfox RC1 ANALOG:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

sigfox RC1 ANALOG - Guide utilisateur / User guide version V2.0.1

3.3. AT commands

A command starts with 2 ASCII characters: "AT", followed by one or more characters and data (see the list below
for the syntax of AT commands available on the modem).
Each command must finish with a "CR" or "CR" "LF" – both are acceptable.
(CR indicates: Carriage Return, LF indicates: Line Feed)
Once the command has been received, the modem will feedback:
<cr><lf> "Data" for ATS type playback control <n> ?, AT/S or AT/V
FR
"O" <cr><lf>, for any other command when this has been accepted.
"E" <cr><lf>, if it refuses the command due to a syntax error, unknown command, unknown range, invalid pa-
rameter, etc.
"CM" <cr><lf>, if it accepts the input in command mode
Table of AT commands:
EN
Command
+++
ATPIN <PIN>
AT/V
AT/N
ATS<n>?
AT/S
ATS<n>=<m>
AT&W
ATO
ATT63 PROVIDER
Example of a set of commands and corresponding responses that can be seen on the terminal:
Syntax
of the order
+++
ATS317=0
ATT63 PROVIDER
ATS317=0
ATS317?
AT&W
ATO
Interpreting the previous example: the user wanted to deactivate the respect of the Duty Cycle after having made
an unauthorized command (answer E), and the registers were unblocked in order to modify the register. The regis-
ter S317 was verified and the parameters were saved before exiting. When exiting command mode, the device will
start a new cycle of emission.
Description
Input request in command mode
Gives access to AT commands if regis-
ter S304 is different of 0
Feeds back the version of the APPLICA-
TIF and RTU software
Feeds back the type of network
Feeds back the content of the n range
Edits the content of all of the user rang-
es in the form of a list.
Transfers the m VALUE to the n range
Saves the current configuration to
non-volatile memory.
Exit command mode
Unblock the operating range
Description
Input request in command mode
Deactivation of the respect of the Duty
Cycle
Unblock the operating range
Deactivation of the respect of the Duty
Cycle
Feeds back the value of the S202 range
Memory request for the state range
Output request in command mode
Reply example
CONNECTING... <cr><lf>
CM<cr><lf>
APP_8230EAA_PRG1706_V01.02.02:RTU_RTU_
WMBUS_868_PRG_1601_V00.00.03
Or
APP_8181AAA_PRG1701_V01.00.02:R-
TU_8120AAB_PRG_1701_V01.00.01
"LoRa" or "SIGFOX" or « WMBUS »
Sn=y where y represents the content of the n
range
/
«O»<cr><lf> if Ok, «E»<cr><lf> if error,
«W»<cr><lf> if coherency error
«O»<cr><lf>, «E»<cr><lf> if coherency error
«O»<cr><lf>, «E»<cr><lf> if coherency error
«O»<cr><lf>
Response Syntax to Next Line
CONNECTING...
CM
E -> This command is not validated (register
no unlocked)
O
O
S317=0
O
O
Page
64
of 86

Publicité

Table des Matières
loading