CONTROLS
Up on the right (see fig. 1 on page 3), cabinets are fitted with a switch for the control of product lighting and with a
remote thermostat/thermometer for temperature control. The remote thermostat displays the temperature existing insi-
de the case and allows temperature control by the use of the appropriate keys.
WARNING: Adjustment is reserved for the technical personnel.
SHELVES: the shelves were designed to bear a maximum load of 225 kg/sq.m. Shelf inclination can be set on 3 dif-
ferent positions (0° - 10° - 20°), by moving the shelf supporting bracket on the display case's uprights.
9. PRESCRIPTIONS AND RESTRICTIONS
Keeping pharmaceutical products in the display case is strictly forbidden (fig.10).
Do not remove protections or panels when it requires the use of tools. IN PARTICULAR, DO NOT REMOVE THE ELEC-
TRIC CONTROL BOARD COVER AND THE SCREWS FASTENING SHELF LIGHTING PLUGS.
Do not expose the display case to atmospheric agents (fig. 15). DO NOT STEP on the cabinet bumper rail. DO NOT
STEP on the top of the cabinet and DO NOT LAY WEIGHTS on it.
Do not spill water directly or indirectly on the display case (fig. 13). Do not touch the equipment with damp or wet
hands or feet; do not use it while barefoot (fig. 14).
ANY OTHER USE NOT EXPRESSLY MENTIONED IN THIS BOOKLET MUST BE CONSIDERED AS HAZARDOUS.
THE MANUFACTURER ASSUMES NO RESPONSIBILITY FOR ANY DAMAGE RESULTING FROM IMPROPER,
INCORRECT OR UNREASONABLE USE.
10. ORDINARY MAINTENANCE
ATTENTION! BEFORE STARTING ANY MAINTENANCE OR CLEANING, DISCONNECT THE EQUIPMENT
FROM THE ELECTRICAL POWER SUPPLY USING THE MAIN WALL CUT-OFF SWITCH (Fig. 17).
IMPORTANT: During maintenance or cleaning operations, be sure that the light in the working area is sufficient and
if necessary, use an additional source of light.
CLEANING THE DISPLAY CASE
1) Every week clean the outer surfaces of the display case with mild soap or detergent in lukewarm water only.
Wipe carefully with a soft cloth. Never clean it using inflammable or scouring agents, alcohol, acetone or solvents.
NEVER CLEAN THE DISPLAY CASE BY THE USE OF WATER JETS. Clean glass surfaces using glass-cleaning
products exclusively. The use of water is not recommended here, as it may cause scale to build up.
CAUTION! NEVER WASH OR CLEAN THE UPPER PART OF THE DISPLAY CASE WITH WATER OR LIQUIDS
2) Every month clean the inside surfaces following the instructions provided in the preceding item:
3) Defrost the display case every three months to let the ice that may have formed between the fins melt. Frost may
otherwise prevent correct operation. Proceed as follows.
· Disconnect the display case from the electrical power supply by the wall main cut-off switch (fig. 19).
· Empty the appliance, store the contents in cold rooms or refrigerators that are adequate for keeping the requisite
preservation temperature.
· Wait until the cold room has reached ambient temperature.
· Clean the inside of the display case thoroughly with mild soap or detergent and lukewarm water. Wipe carefully
20