WARNING NOTICES

1.
DO NOT operate this machine unless you have been fully trained in its safe
use.
2.
DO NOT operate the machine on soft, slippery or sloping ground unless
adequate precautions have been taken.
The stabilisers are designed to operate on firm level ground with a minimum
bearing strength of 50N/cm
The maximum load imposed by an outrigger is 12.5kN.
Advice should be obtained from UpRight as to the type of supports and
precautions required before attempting to operate the machine outside
these parameters.
3.
DO NOT use any equipment in the basket to increase the reach or working
height of the machine, e.g. ladders.
4.
DO NOT fit any additional equipment to the machine that would increase
the wind loading, e.g. notice boards.
5.
DO NOT use the machine for any application that may produce special loads
or forces: the manufacturer, UpRight Powered Access, must be consulted for
approval of special applications prior to use.
6.
DO NOT use the machine close to live electrical conductors. The minimum
safe working distance for a machine working near overhead power cables is
the maximum extended length of the booms plus 15 metres, measured
with the booms pointing towards the lines, i.e. safe working distance for the
TL49K is 24 metres. It is the operator's responsibility to ensure that, when
working in the vicinity of live overhead high-voltage lines, the minimum safe
working distance is maintained. Erect a simple barrier tape at the safe
distance.
7.
WORKING CLOSE TO POWER CABLES – if work has to be carried out at less
than the safe working distance, the operator must ensure that the
electricity supply has been switched off. Before commencing work, a
written permit to work must be obtained from the owners of the power
cables or the responsible authority.
8
.
2
15m
15m
24m
26m