Télécharger Imprimer la page

Danby Designer DPAC120010 Guide D'utilisation Et Soins De Propriètaire page 9

Publicité

Les langues disponibles

Les langues disponibles

OPERATING CONDITIONS:
The unit must be operating within the following
temperature ranges:
MODE
TEMPERATURE
Cool
17°C - 30°C (62°F - 92°F)
Dehumidify
13°C - 32°C (54°F - 92°F)
Heat
5°C - 30°C (41°F - 88°F)
DRY OPERATION:
The dry (dehumidifying) operation removes moisture
from the air. To activate the dry operation;
1) Direct-drain must be used during this operation. To
set up direct-drain, refer to Direct Drain on the
previous page.
2) Turn on the unit, and press the MODE button until
the Dry Indicator is lit.
HEAT OPERATION:
The heating operation has a set temperature range
between 5°C and 30°C (41°F and 88°F). To activate
the heating operation;
1) Press the MODE button until the Heat Indicator is
lit.
2) Use the Temp. Increase or Temp. Decrease buttons
to select desired room temperature.
3) Use the Fan Speed Selection button to increase or
decrease the fan speed used during operation.
FAN OPERATION:
The fan operation does not air condition, heat, or
dehumidify the room; instead, it provides air
circulation. To activate the fan operation;
1) Press the MODE button until the Fan Indicator is
lit.
2) Use the Fan Speed Selection button to increase or
decrease the fan speed used during operation.
3) Use the Temp. Increase or Temp. Decrease buttons
to select desired room temperature.
TIMER OPERATION:
The timer is programmed to activate/deactivate after
the selected amount of hours has passed.
The minimum timer length is 30 minutes, after which
the timer increases in 30 minute (0.5 hour)
increments, up to 10 hours. Past 10 hours, the timer
increases in one (1.0 hour) hour increments up to a
maximum of 24 hours. Increasing the timer past 24
hours returns the timer to '0' (off).
OPERATING INSTRUCTIONS (cont'd)
Setting the Auto-On Timer:
1) When the air conditioner is off, press the Timer On
button.
2) Continue to press (or hold down) the Timer On
button to select the desired hours-from-now for the
unit to start operation.
Setting the Auto-Off timer:
1) When the air conditioner is on, press the Timer Off
button.
2) Continue to press (or hold down) the Timer Off
button to select the desired hours-from-now for the
unit to stop operation.
Important Note on the Timer Operation:
• The timer registers a selection after 5 seconds of the
Timer On or Timer Off button being pressed.
COOL OPERATION:
The cooling operation has a set temperature range
between 17°C and 32°C (62°F and 92°F). To activate
the cooling operation;
1) Press the MODE button until the Cool Indicator is
lit.
2) Use the Temp. Increase or Temp. Decrease buttons
to select desired room temperature.
3) Use the Fan Speed Selection button to increase or
decrease the fan speed used during operation.
NOTE: Water drainage is not needed during cooling
operation; if you do use direct drain during the
cooling operation, the energy efficiency will be
reduced. However, in extremely high humidity
conditions (e.g. above 85% RH), condensed water
may begin to accumulate in the bottom tray. When the
bottom tray is full, the unit stops running and sounds
a signal (8 beeps). To restart the unit, see Direct
Drain on previous page.
8

Publicité

loading