WEB INTERFACE
Control setting
Test Measuring chain:
The sensor CAP65 is equipped with a piezo speaker to test the acoustic integrity of the microphone.
This string must be calibrated at the installation
This test will then be done at each startup and randomly. In case of default, a message will be integrated
into the history.
If the sensor such as CAP40 and CAP90 does not have this feature, disable this self test, by turning off the
button
Enable.
General Purpose Output 1/ General Purpose Output 2:
The RJ45 output GPO1/GPO2 connector has two low voltage relay outputs to connect different
complementary elements (beacon, alarm), see 5 page 11.
This output allows to connect and supply the figurative displays AFF04 / AFF08 / AFF12.
These two "GPO 1 and 2" relays are programmable at the same time in acoustic level, in weighting A or
C and in Leq 1s, 1min, 5min, 10min, 15min or 60 min.
Email Alerts setting
This page allows you to configure 3 types of alarms : E-mail Alert 1 ; E-mail Alert 2 ; E-mail Alert 3
AMIX
Identification:
This part allows to inform the site and the
particular localization on the site (case of
multi-room complex).
These two pieces of information will be
included in the event log and level
histories.
Run Process
.
On each alarm you can program:
Reference:
1s,1min,5min ,10 min,15min and 60 min.
Weighting A /Weighting C :
C.
Threshold:
alarm in dB.
Alert Delay:
moment or an overshoot is detected and
the time or an alarm is generated.
Repetition in Hour:
the hour before sending an e-mail
information.
31
The leq referent is: leq
Weighting A or
The trigger threshold of the
The delay time between the
Number of alerts in
AFFseries-3