INSTALLATION GUIDE
C/ Lost IP address:
If you have changed the IP address of the AFF-series-3 and have lost it, then you can find it by following
the procedure below.
Press for one second the switch 8 (on the side of the display) noted IP CONTROL, the IP address will
be displayed on the front panel displays.
If you press for more than 5 seconds, the IP address returns to the ex-factory address:
192.168.0.122
MEASURING RANGE
With A weighted, Leq level range is from 60 dB(A) to 120 dB(A).
With C weighted,Leq level range is from 70 dB(C) to 130 dB(C).
ERRORS LISTING
Error listing which can be displayed by control display (B).
E2: Sensor link defect.
E3: Low internal battery voltage. Replace quickly.
AMIX
24
Next
AFFseries-3