Service
With cleaning and maintenance on the machine, the
power cable should be disconnected from the supply.
Th e fi ne fi lters should be changed at least once per year.
If the machine is used with a microfi lter/HEPA fi lter, this
should be changed every 300 running hours. Use breathing
protection when changing the fi lter. Care must be taken
during the fi lter change not to expose unprotected persons
to harmful dust. Used fi lters should be sealed in a plastic
sack and disposed properly.
Check regularly that the electrical cable is not damaged.
Th e DC 5800i should be performance tested at least once
Accessories
Description
Fine fi lter, polyester
Branch pipe
Vacuum valve
Silencer 4942
Warranty
Th e warranty period for this machine is two years and co-
vers manufacturers faults. Th e warranty is valid under the
condition that the machine is used under normal conditions
on the task for which it was designed and is maintained
properly. Normal
wear is not covered by this warranty. Service performed
by other than Dustcontrol or its autho-rized agent voids
Part no
4292
3036
8001
DC 5800i 9.2 kW P - 10
per year because it may be used with hazardus materials.
Worn parts must be replaced. Dustcontrol is not responsible
for machines that are equipped with other than original
spare parts.
Th e turbopump has a very long maintenance free service life.
After approximately 10 000 running hours, the radial seal
between the motor and pump housing should be greased.
Bearings and seals in the motor and turbopump should
be checked and lubricated. Parts worn beyond serviceable
tolerances should be replaced with genuine spare parts.
When DC 5800i 9.2 kW P is used for semimobile
system must the pipesystem be equipped with
a silencing vacuum valve.
Other accessories — see Dustcontrol catalo-
gue.
automatically the warranty. No other warranty express or
implied is applicable.
Part No 9446