NOTICE
Electrostatic discharge (ESD)!
This product contains electrostatic sensitive
components that can be destroyed by electrostatic
discharge (ESD).
It is essential to observe the safety precautions for
handling ESD-sensitive components
Never touch connector pins without ensuring proper
grounding
Wear a grounded ESD wristband when handling
product connections
NOTICE
Damage to the product due to incorrect wiring!
The incorrect wiring of inputs or outputs can cause
damage to the unit or to peripheral devices.
Comply with the pin layouts and specifications of
the product
Assign only pins or wires that will be used
"Specifications", Page 27
Further information:
5.3
Product overview
The connections on the rear panel of the device are
protected by dust protection caps from contamination and
damage.
NOTICE
Contamination or damage may result if the dust
protection caps are missing!
If no dust protection caps are fitted to unused
connections, this may impair the proper functioning of
the contacts or destroy them.
Remove dust protection caps only when connecting
measuring devices or peripherals
If you remove a measuring device or peripheral, re-
attach the dust protection cap to the connection
The type of connections for encoders may
vary depending on the product version.
HEIDENHAIN | GAGE-CHEK 2000 | Installationsanleitung | 12/2018
Rear panel without dust protection caps
Further information:
"A", Page 4
Connections:
5
D-sub connections for encoders, one input enabled by
default, another two inputs can be enabled optionally
X1 to X3
: device variant with 15-pin D-sub connections for
, 11 μA
encoders with 1 V
PP
X21 to X23
: Device variant with 9-pin D-sub connections
for encoders with a TTL interface
X1
X2
X21
,
,
: Device variant with two 15-pin D-sub connec-
tions for encoders with 1 V
connection for encoders with TTL interface
7 X32
: USB 2.0 Hi-speed connection (type A) for printers,
input devices or USB mass storage
10
Speaker
8
Functional ground connection as per IEC/EN 60204-1
6 X116
: RJ45 Ethernet connection for communication and
data exchange with subsequent systems or PC
4 X113
: 15-pin D sub connection for touch probes (e.g.,
HEIDENHAIN touch probe)
9 X100
: Power switch and power connection
5.4
Connecting encoders
For encoders with an EnDat 2.2 interface:
If the corresponding encoder input has
already been assigned to an axis in the device
settings, then the encoder is automatically
detected upon restart, and the settings are
adapted. Alternatively, you can assign the
encoder input after you have connected the
encoder.
Comply with the pin layout
Further information:
"1 V
PP
Page 182
Further information:
"TTL", Page 182
Remove and save the dust protection cap
Route the cables depending on the mounting variant
Further information:
"Assembly of the product", Page 23
Connect the encoder cables tightly to the respective
connections
"Product overview", Page 25
Further information:
If the cable connectors include mounting screws, do
not overtighten them
or EnDat 2.2 interface
PP
interface and one 9-pin D-sub
PP
, 11 µA
, EnDat 2.2",
PP
25

Publicité