1.
Fig. 6 Electrical wiring
1. 12VDC for built-in LED lighting
2. Any extra equipment such as lighting, AUX
3. Main power supply to Stella
Type: Steam Shower Stella 2.2 kW
200 - 208 - 230 - 240 V~
Type: Steam Shower Stella 4.5 kW
200 - 208 - 230 - 240 V~
Type: Steam Shower Stella 4.5 kW
400 - 415 V 2N~
400-415 V
2N~
kW
Amp
mm²
AWG
2,2
-
-
-
4,5
10
1.5 14
Don´t forget to earth (ground)!
Vergessen Sie nicht zu erden!
Glöm inte att jorda!
Nóubliez pas la mise à la terre!
Fig. 7 Connections diagram
2.
3.
G
A
200-240 V~
G
A
200-240 V~
G
A
L1 L2
400-415 V 2N~
200-208 V~
230-240 V~
Amp
mm²
AWG
Amp
mm²
11
2.5
-
10
1.5
23
6
20
4
-
1C
G
A1A2
A3A4
*
AUX0
200-
240 V~
1B
F1 F2
P1 P2 N1 N2
200-
240 V~
Transformer
Fig. 8 Alternative wiring, lighting
A. Internal LED controlled from Elite control panel
B. Internal LED controlled from external switch
1A
B C D
1A
B C D
1A
B C D
N
AWG
14
12
Fig. 9 Connection
1. Steam column, Stella
*
Max 10A
2. Main power switch
3. Electrical distribution board
4. Residual current device max. 30mA
5. Power switch
6. 12VDC Transformer, min. 20 W
7. Extra equipment (AUX) max. 10 A
A.
1E
+ -
3
4 5
12VDC
Inside Stella
Outside Stella
1.
2.
ON
OFF
3.
<30 mA
25
B.
1E
+ -
3
4 5
12VDC
Inside Stella
Outside Stella
Transformer
200-
240 V~
7.
6.
12VDc
20W
ON
OFF
5.
4.