Technical specifications

The steam generator is equipped with:
Aluminium water reservoir
Water reservoir volume: 2 litres
Acid-proof stainless steel tubular elements
Automatic emptying 60 minutes after the steam bath has
been switched off
Automatic flushing after emptying
2-division output
Electronic water level regulation
Electronic level protection
Acid-proof stainless steel electrodes
Continuous steam production
Always use the correct power output, regardless of the water
quality and level
Built-in temperature cut-out
Built-in dirt filter
Automation for remote control
Rinse-proof design
IP class X5
Error code clearing
Automatic emptying during operation, adjustable
Built-in Wi-Fi module 2412-2462 MHz, <20dBm. The product
must be installed and used so as to maintain a minimum
distance of 20 cm from the user.

Correct power output in relation to room volume

Max. recom. steamroom volume m³
Toughened glass
lightweight wall,
Elysée/Excellent
kW
room, etc.
without
with venti-
venti-
lation
lation
2.2
-
2,5
4.5
4
5,5
Table. 1 Output and room volume
Heavyweight wall
Steam
made of concrete,
prodn.
stone, tiles, etc.
with venti-
without
lation
ventilation
-
1,5
2,5
3,5

Pipework installation

To be done by an authorised plumber.

Water connection

Preparatory pipe installation. Always use approved connections
and hoses for fixed installation. Install Stella in Wet ZONE 1
A = Incoming pipe connection G 1/2",
B = Option of overhead shower
C = Incoming electricity and option of extra control panel
kg/h
3
5,5
ZONE 1
Fig. 2 Dimensions for installation, water and electrical connection
cold and hot
x 4
cc 90 mm
B. C.
A.
min 300 mm
cc 90 mm
water

Publicité

Table des Matières
loading