Replacing the Lamp (CD086, CD087, CD088, CB921)
1.) Switch Off and disconnect the appliance from the power supply
2.) Remove the plastic cover
3.) Twist the lamp in its socket and release
4.) Remove the lamp and replace the new one of the same power rating
5.) Replace the plastic cover
Troubleshooting
If your POLAR appliance develops a fault, please check the following table before making a call to the
Helpline.
Fault
The appliance is not
working
The appliance turns
on, but the
temperature is too
high/low
The appliance is
leaking water
The appliance is
unusually loud
Probable Cause
The unit is not switched on
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
Too much ice on the evaporator
Condenser blocked with dust
Doors are not shut properly
Appliance is located near a heat
source or air flow to the
condenser is being interrupted
Ambient temperature is too high
Unsuitable foodstuffs are being
stored in the appliance
Appliance is overloaded
The appliance is not properly
levelled
The discharge outlet is blocked
Movement of water to the drain is
obstructed
The water container is damaged
Loose nut/screw
The appliance has not been
installed in a level or stable
position
Check the unit is plugged in correctly and switched on
Call POLAR agent or qualified Technician
Replace the fuse
Check power supply
Call POLAR agent or qualified Technician
Defrost the appliance
Call POLAR agent or qualified Technician
Check doors are shut and seals are not damaged
Move the refrigerator to a more suitable location
Increase ventilation or move appliance to a cooler position
Remove any excessive hot foodstuffs or blockages to the
fan
Reduce the amount of food stored in the appliance
Adjust the screw feet to level the appliance (if applicable)
Clear the discharge outlet
Clear the floor of the appliance (if applicable)
Call POLAR agent or qualified Technician
Check and tighten all nuts and screws
Check installation position and change if necessary
Action
UK