Télécharger Imprimer la page

Hayward ZPD Série Manuel D'installation page 9

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Paragraph 8 – Timed Dosage (Frequency signal input "TRIGGER" activated)
Programming
PROG
Configuration
Configuration
Pump functions
-
+
Pump functions
Time
-
Time
-
Quantity
100ml
-
Time
g.hh.mm
-
Delay
0.01.50
-
Time
g.hh.mm
-
interv.
0.01.50
Trigger Mode
Trigger Mode
-
N. Open
N. Open
Pause Input Mode
Trigger Mode
-
Trigger Mode
N. Closed
Trigger Mode
Disable
Display during Operation
Operating mode
Timer
Alarms and statuses
Liv = level alarm
Flow = flow alarm or
....Release wait
Hayward Flow Control
After receipt of the TRIGGER signal set, the pump doses a quantity
that can be programmed in ml. It is possible to set a delay time before
the dosing (Delay) and the interval between subsequent dosings
(Interv.) as illustrated in the diagram:
By setting for example an Interval. time = 0, a system is obtained in
which the programmed quantity is dosed after each TRIGGER signal
(with any delay that has been set):
+
+
+
It is possible to start the dosing by pressing the + key, which, in
practice, simulates the Trigger signal.
-
The Trigger signal can be set to N. Open (it is activated when the
input passes from the open to the closed mode) or to N. Closed (it is
-
activated when the input passes from the closed to the open mode).
The Trigger signal is locked during dosing (its receipt is neither stored
nor managed).
The Pause (Remote input) input cannot be programmed and its
activation stops the dosing, while its further deactivation makes the
system wait again for the Trigger signal for a new dosing.
The dosage frequency can be modified while the pump is operating,
by pressing the
frequency, or the
FLOW
Programmed value
sensor status
Quantity in ml
F F
F
Timer
7,0 ml
Stop
P 0%
Value of the dosing in
progress
Pump status
Dry = pump starting up
Stop = pump stop
Restart = pump restart
www.haywardflowcontrol.com
Trigger
Delay
Interv.
Trigger
Delay
keys at the same time to increase the
keys to decrease it.
Display during Setting (MODE key)
Q.tà
20,0ml
Percentage of
strokes/min
max
Value of the dosing percentage,
which can be modified by
pressing the + or – keys
Operation
Quantity
Release
Delay
Operating mode
The following are shown in sequence:
quantity to dose, delay in d.hh.mm.
and interval in d.hh.mm
20,0ml
P 100%
1-888-INDL (1-888-429-4635)
Dosing value
Programmed
quantity in m
l
ZPDIOM
Pg. 7 of 12

Publicité

loading