TECHNICAL CHARACTERISTIC TABLES
BURNERS
N°
DESCRIPTIONS
1
RAPID
2
SEMI-RAPID
3
AUXILIARY
4
TRIPLE RING
5
DOUPLE RING
Short title or reference to the measurement and calculation methods used to establish compli-
ance with the above requirements.
The performance of each individual burner is calculated according to standard EN 30-2-1 + A1:2003 +
A2:2005
The total efficiency of the hob is calculated according to the EU Regulation 66/2014 Par. 2.2
The efficiency is calculated only for the burners with a nominal capacity exceeding 1,16 KW ( EN 30-2-1
+ A1:2003 + A2:2005; Par. 4.1)
Information which is relevant to the customer to minimize the energy consumption during usage:
Energy Saving Tips: use pots having flat base, Use pots with proper size, use pots with lid, minimize the
amount of liquid or fat, when liquid starts boiling reduce the setting.
NORMAL
PRESSURE
GAS
mbar
G30 - G31
28 - 30
G20
20
G30 - G31
28 - 30
G20
20
G30 - G31
28 - 30
G20
20
G30 - G31
28 - 30
G20
20
G30 - G31
28 - 30
G20
20
NORMAL
I N J E C T O R
RATE
DIAMETER
g/h
L/h
1/100 mm
225
-
85
-
290
115
126
-
65
-
165
97Z
71
-
50
-
99
72
278
-
101
-
367
145
255
-
93
-
334
137
13
TAPE BY
NOMINAL HEAT
PASS
INPUT (W)
DIAMETER
1/100 mm
Max.
Min.
42
3000
950
Reg.
3000
950
31
1750
600
Reg.
1750
600
27
1000
450
Reg.
1000
450
60
4200
2100
Reg.
4200
2100
60
3500
2100
Reg.
3500
2100
EE
gas
burner
(%) *
57.1
57.3
N.D./
53.8
55.2