7. Further special functions
7.1 Resetting the lock
This programming command can only be executed while the lock is opened using the key. This procedure
deletes all settings of the lock (user code, courier code, double code, silent alarm, opening delay and opening
standby time), only the master code and the audit remain unchanged.
Step
Open the lock using the key
1.
Press P and enter
2.
Press P0 and enter
3.
Close the lock again by means of the key and mount the rotary handle
4.
7.2 Security block out feature
The lock is equipped with a take-off contact (AHK), which is tripped when opening the input unit (e.g. to
replace the battery or after a manipulation); after that it is displayed with the manipulation signal for each
opening/operation until the acknowledgment. If the signal mentioned above is displayed even if no battery
replacement has been performed, the input unit might have been manipulated. If you are not sure, whether
there has been a manipulation or not, consult an authorized service!
Step
Press P
1.
Enter your 8-digit master code, e.g. 00678912 and press enter
2.
Enter P9 and press enter
3.
The take-off contact is now deactivated
4.
7.3 Software
The lock has an additional mini-USB interface on the input unit. The lock can be programmed via this interface using
the PC software available as an accessory.
The following functions are available when using the additional PC software:
1) Reading out audit
2) Programming the lock settings using software
Please contact your local dealer for further details.